Siemens SINUMERIK 840D sl Series Diagnostics Manual page 140

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
Definitions:
With active radius compensation, only up to cubic polynomials are permissible for the
geometry axes. In this case no 4th or 5th degree polynomials can be programmed.
Reactions:
- Correction block is reorganized.
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm at block end.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
10962
Channel %1 block %2 function %3 not possible with path correction
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Funktionsname
Definitions:
With this software release, the specified function can not yet be used together with tool
radius compensation. Please modifiy the part program or obtain a higher software ver-
sion.
Reactions:
- Correction block is reorganized.
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm at block end.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
10980
Channel %1 block %2 orientation smoothing not possible
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In the case of active path-relative orientation interpolation with ORIPATH, orientation
smoothing cannot be activated. This means that in the 34th modal G code group
G code OSOF must be active.
Reactions:
- Correction block is reorganized.
- Interpreter stop
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
12000
Channel %1 block %2 address %3 programmed repeatedly
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source string of the address
Definitions:
Most addresses (address types) may only be programmed once in an NC block, so that
the block information remains unambiguous (e.g. X... T... F... etc. - exception: G and M
functions).
Reactions:
- Correction block
- Interface signals are set.
- Alarm display.
2-140
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved