PROFIsafe: MD %1[%2] maximum number of F user data (%3 bits) exceeded.
Parameters:
%1 = MD name
%2 = MD array index for MD name
%3 = Maximum F user data bits.
Definitions:
The parameterized data indicated in the machine data are outside the F user data range
of the F module.
Note
When machine data PROFISAFE_IN/OUT_ADDRESS is displayed, the sub slot address
parameterized in it will exceed the F user data range of the F module.
Reactions:
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Correct the MD.
Program Con-
Switch control OFF - ON.
tinuation:
27207
PROFIsafe: MD %1[%2] max. sub slot number: %3 exceeded
Parameters:
%1 = MD name
%2 = MD array index for MD name
%3 = Max. number of sub slots
Definitions:
The sub slot parameterized in the indicated machine data exceeds the max. permissible
number of sub slots per PROFIsafe module.
Reactions:
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Reduce the number of sub slots by changing the splitting of F user data of the PROFIsafe
module.
Program Con-
Switch control OFF - ON.
tinuation:
27208
PROFIsafe: MD %1[%2]: max. sub-slot address %3 exceeded.
Parameters:
%1 = MD name
%2 = MD array index
%3 = Maximum sub-slot address.
Definitions:
A sub-slot address was entered in the MD that is too high. The entered value must not
exceed the displayed maximum sub-slot address.
Reactions:
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.