Siemens SINUMERIK 840D sl Series Diagnostics Manual page 901

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
%2 = Drive number
Definitions:
The cam modulo range parameterized for a rotary axis via MD 1305:
$MD_SAFE_MODULO_RANGE (actual value range for safe cam with rotary axes) vio-
lates the rule stating that only integral multiples of 360 degrees may be set.
Reactions:
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Change parameterization of
the cam modulo range in MD 1305: $MD_SAFE_MODULO_RANGE (actual value range
for safe cam with rotary axes).
Program Con-
Switch control OFF - ON.
tinuation:
301708
Axis %1 drive %2 actual value synchronisation not allowed
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The actual value synchronization for drift/slippage in MD 1301:
$MD_SAFE_FUNCTION_ENABLE (safe functions enable) is deselected. This is only
allowed with SBH/SG monitoring, since the absolute actual position is irrelevant for this
type of monitoring. However, safe end position and/or cam monitoring is also selected.
Reactions:
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Deselect actual value syn-
chronization for drift/slippage or the safe end position and/or safe cam monitoring in MD
1301: $MD_SAFE_FUNCTION_ENABLE (safe functions enable).
Program Con-
Switch control OFF - ON.
tinuation:
301709
Axis %1 drive %2 submodule with integrated linearization invalid
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
If a submodule with integrated linearization is used, all submodules on the module must
use the integrated linearization. A submodule with integrated lineearization was found.
However, not all submodules have this linearization.
Reactions:
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Replace the submodule.
Program Con-
Switch control OFF - ON.
tinuation:
301710
Axis %1 drive %2 resolution SSI motor measuring system invalid
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-901

Advertisement

Table of Contents
loading

Table of Contents