08/2005
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE974, CYCLE977, CYCLE978,
CYCLE979, CYCLE994
Remedy:
The difference between actual and setpoint value is smaller than lower tolerance limit
(parameter _TLL).
62306
Channel %1 Block %2: Permissible measuring difference exceeded
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE971, CYCLE972, CYCLE974,
CYCLE977, CYCLE978, CYCLE979, CYCLE982, CYCLE994
Remedy:
The difference between actual and setpoint value is larger than tolerance parameter
_TDIF, tool data are not corrected.
62307
Channel %1 block %2: Maximum number of characters per line exceeded.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE105
Insufficient number of characters per line.
Remedy:
Increase the value in _PROTFORM[1]
62308
Channel %1 Block %2: Variable column width not possible
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE105.
Unable to generate variable column widths, as no header available.
A fixed column width of 12 characters is used.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Complete the header in _PROTVAL[0].
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
62309
Channel %1 Block %2: Insufficient column width
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE105.
The value to be logged is larger than the column width.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Adjust _PROTFORM[5] or change the header at variable column width.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
62310
Channel %1 block %2: The max. number of characters per line is limited to 200
characters per line
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-513