Siemens SINUMERIK 840D sl Series Diagnostics Manual page 210

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
• New definition of the pole with polar angle and pole radius, referring to the reference
point selected with the G function. G110 ... last programmed point in the plane, G111 ...
zero point of the current work, G112 ... last pole
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Correct NC part program. The permissible input range for the polar angle is between the
values -360 degrees and +360 degrees with a resolution of 0.001 degrees.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14270
Channel %1 block %2 pole programmed incorrectly
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
When defining the pole, an axis was programmed that does not belong to the selected
processing level. Programming in polar coordinates always refers to the plane activated
with G17 to G19. This also applies to the definition of a new pole with G110, G111 or
G112.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Correct the NC part program. Only the two geometry axes may be programmed that
establish the current machining plane.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14280
Channel %1 block %2 polar coordinates programmed incorrectly
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The end point of the displayed block has been programmed both in the polar coordinate
system (with AP=..., RP=...) and in the Cartesian coordinate system (axis addresses X,
Y,...).
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Correct the NC part program - the axis motion may be specified in one coordinate system
only.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14290
Channel %1 block %2 polynominal degree greater than 5 programmed for polynom-
inal interpolation
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A polynominal degree greater than five was programmed for the polynominal interpola-
tion. You can only program polynomials up to the 5th degree.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
2-210
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005