Siemens SINUMERIK 840D sl Series Diagnostics Manual page 314

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
7: Tool-related protection zone is defined as inside protection zone.
8: Incorrect parameter used.
9: Protection zone to be activated is not defined.
10: Incorrect modal G code used for protection zone definition.
11: Contour definition incorrect or frame activated.
12: Other errors not specified further.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Please inform the authorized personnel/service department. Modify definition of the pro-
tection zone and check MD.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
18001
Channel %1 block %2 channel-specific protection zone %3 incorrect. Error code
%4
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of the channel-specific protection zone
%4 = Error specification
Definitions:
There is an error in the definition of the protection zone. The error number gives the spe-
cific reason for the alarm. The following meanings apply:
1: Incomplete or conflicting contour definition.
2: Contour encompasses more than one surface area.
3: Tool-related protection zone is not convex.
4: If both boundaries are active in the 3rd dimension of the protection zone and both limits
have the same value.
5: The number of the protection zone does not exist (negative number, zero or greater
than the maximum number of protection zones).
6: Protection zone definition consists of more than 10 contour elements.
7: Tool-related protection zone is defined as inside protection zone.
8: Incorrect parameter used.
9: Protection zone to be activated is not defined.
10: Incorrect modal G code used for protection zone definition.
11: Contour definition incorrect or frame activated.
12: Other errors not specified further.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Please inform the authorized personnel/service department. Modify definition of the pro-
tection zone and check MD.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
18002
Channel %1 block %2 NCK protection zone %3 cannot be activated. Error code %4
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of NCK protection zone
%4 = Error specification
Definitions:
An error has occurred on activating the protection zone. The error number gives the spe-
cific reason for the alarm.
2-314
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005

Advertisement

Table of Contents
loading

Table of Contents