Siemens SINUMERIK 840D sl Series Diagnostics Manual page 17

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
%3 = System error number
Definitions:
With this alarm, internal alarm states are displayed that, in conjunction with the trans-
ferred error number, provide information on the cause and location of the error.
Reactions:
- Mode group not ready.
- Local alarm reaction.
- Channel not ready.
- Interface signals are set.
- Alarm display.
Remedy:
Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Program Con-
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
tinuation:
1017
Channel %1 axis %2 system error %3
Parameters:
%1 = Channel number
%2 = Axis number
%3 = System error number
Definitions:
With this alarm, internal alarm states are displayed that, in conjunction with the trans-
ferred error number, provide information on the cause and location of the error.
Reactions:
- Alarm display.
Remedy:
Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
1018
Floating point arithmetic error in channel %1 task %2 station %3 FPU state %4
Parameters:
%1 = Channel number
%2 = Task ID
%3 = Station priority
%4 = FPU status
Definitions:
The floating point unit of the processor has found a computational error.
Reactions:
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Alarm reaction delay is canceled.
Remedy:
Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Program Con-
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
tinuation:
1019
Floating point arithmetic error at address %3 in channel %1 task %2 FPU state %4
Parameters:
%1 = Channel number
%2 = Task ID
%3 = Code address of operation that triggered the error
%4 = FPU status
Definitions:
The floating point unit of the processor has triggered an exception on account of a compu-
tational error.
Reactions:
- NC not ready.
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms