Siemens SINUMERIK 840D sl Series Diagnostics Manual page 93

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
Reactions:
- Alarm display.
Remedy:
You can change the mode by pressing the Reset key and repeating the mode change.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
10240
[up to SW 3.x only] Mode group %2 channel %1 mode change not possible
Parameters:
%1 = Channel number
%2 = Mode group number
Definitions:
The mode change would cause the "reorganization" of the preprocessor buffer. This is not
possible at present, because a complex geometry section is being processed.
Reactions:
- Alarm display.
Remedy:
You can change the mode by pressing the Reset key and repeating the mode change.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
10241
[up to SW 3.x only] Mode group %2 mode change in active channel %1 not possible
Parameters:
%1 = Channel number
%2 = Mode group number
Definitions:
The channel is not in the stopped state. Reorganization is therefore impossible.
Reactions:
- Alarm display.
Remedy:
Press NC Stop and perform the action again.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
10242
[up to SW 3.x only] Mode group %2 mode change in channel %1 not possible at this
time
Parameters:
%1 = Channel number
%2 = Mode group number
Definitions:
The internal state of the indicated channel is not uniquely defined (e.g. in initialization
mode or waiting for an acknowledgement from the sequence control system).
Reactions:
- Alarm display.
Remedy:
You can change the mode by pressing the Reset key and repeating the mode selection.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
10243
[up to SW 3.x only] Channel %1: mode group %2 cannot change mode
Parameters:
%1 = Channel number
%2 = Mode group number
Definitions:
The requested mode change cannot be executed because NC functions are still running
in the other channel, e.g. part program execution.
Reactions:
- Alarm display.
Remedy:
You can change the mode by pressing the Reset key and repeating the mode selection.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
10249
[up to SW 3.x only] Mode group %2 channel %1: mode change command canceled
Parameters:
%1 = Channel number
%2 = Mode group number
Definitions:
An error occurred while a mode change command was active, with the result that the
sequence could not be continued.
Reactions:
- Mode group not ready.
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-93

Advertisement

Table of Contents
loading

Table of Contents