Overview of Alarms
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Alarm reaction delay is canceled.
Remedy:
Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Program Con-
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
tinuation:
1030
System error in link module error code %1 error type %2
Parameters:
%1 = Hex-Zahl Link-Error
%2 = Hex-Zahl Link-Error-Type
Definitions:
This alarm is not a user error. An internal error has occurred in the software of the link
module. Two parameters are output with this error for debugging purposes. They provide
information about the cause and location of the error.
Reactions:
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Program Con-
Switch control OFF - ON.
tinuation:
1031
Link module generated an unspecified error %1 NCU %2 %3 %4
Parameters:
%1 = Hex-Zahl unspecified status in stateOfLinkModules
%2 = NCU number
%3 = Command from link module to NCK
%4 = Status of own link
Definitions:
This alarm is not a user error.
• 1. If NCU== 0 -> A parameter not equal to zero was not found
• 2. If NCU not equal to zero -> An error which the NC was not able to interpret in the con-
nection to this NCU. The error is output as a number. It is possible that the NCU link mod-
ule is running a newer software version than the NC.
The other parameters are used for error localization in the NC/LINK-MODUL software.
Reactions:
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Program Con-
Switch control OFF - ON.
tinuation:
1100
No valid firmware
2-18