Siemens SINUMERIK 840D sl Series Diagnostics Manual page 422

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
• Incorrect SPL assignment (bit value equals zero)
Reactions:
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Correct the MD.
Program Con-
Switch control OFF - ON.
tinuation:
27204
PROFIsafe: double assignment MD %1[%2] - MD %3[%4]
Parameters:
%1 = MD name 1
%2 = MD array index for MD name 1
%3 = MD name 2
%4 = MD array index for MD name 2
Definitions:
A double assignment has illegally been parameterized in the specified machine data:
$A_INSE parameterized on DMP as well as PROFIsafe modules. Involved MDs:
• MD $MN_SAFE_IN_HW_ASSIGN
• MD $MN_PROFISAFE_IN_ASSIGN
$A_INSE parameterized on several PROFIsafe modules. Involved MD:
• MD $MN_PROFISAFE_IN_ASSIGN
Reactions:
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Correct the MD.
Program Con-
Switch control OFF - ON.
tinuation:
27205
PROFIsafe: number of signals in MD %1 [%2] <> MD %3[%4]
Parameters:
%1 = MD name 1
%2 = MD array index for MD name 1
%3 = MD name 2
%4 = MD array index for MD name 2
Definitions:
The parameterized number or the signals used must be the same in both machine data.
Reactions:
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Correct the MD.
Program Con-
Switch control OFF - ON.
tinuation:
2-422
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005