Siemens SINUMERIK 840D sl Series Diagnostics Manual page 235

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
15
SynSpi option
16
Repos option
17
Spline option
18
Involute option
19
Poly option
20
Compress option
23
Masl option
24
ExtLang or ExtLanguage option not activated
25
TechCycle option
26
Liftfast option
27
ProgAccel option
33
AllAsupSynact option
34
CmdAxSpind option
35
Mea2 option
36
ProgAnaOut option
37
OptAaTOff option
41
MachineMaintenance option
42
PathFeedSAInput option
45
ElecTransfer option
46
Cut3D option
47
CDA option
48
Reserved: generic coupling option
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program, retrofit option.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14782
Channel %1 block %2 non-active function used (identification %3)
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Fine ID
Definitions:
A non-active function is used in the block
Brief description of the identification
1
Transformation
2
H number of the tool
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
• Modify part program.
• Activate function.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14790
Channel %1 block %2 axis %3 programmed by PLC
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-235

Advertisement

Table of Contents
loading

Table of Contents