Bits 3 to 0—Operate in the same way as for the normal SCI. For details, see section 16.2.7, Serial
Status Register (SSR).
However, the setting conditions for the TEND bit, are as shown below.
Bit 2
TEND
Description
0
Transmission is in progress
[Clearing conditions]
When 0 is written to TDRE after reading TDRE = 1
When the DMAC or DTC is activated by a TXI interrupt and write data to TDR
1
Transmission has ended
[Setting conditions]
Upon reset, and in standby mode or module stop mode
When the TE bit in SCR is 0 and the ERS bit is also 0
When TDRE = 1 and ERS = 0 (normal transmission) 2.5 etu after transmission of a
1-byte serial character when GM = 0 and BLK = 0
When TDRE = 1 and ERS = 0 (normal transmission) 1.5 etu after transmission of a
1-byte serial character when GM = 0 and BLK = 1
When TDRE = 1 and ERS = 0 (normal transmission) 1.0 etu after transmission of a
1-byte serial character when GM = 1 and BLK = 0
When TDRE = 1 and ERS = 0 (normal transmission) 1.0 etu after transmission of a
1-byte serial character when GM = 1 and BLK = 1
Note: etu: Elementary Time Unit (time for transfer of 1 bit)
(Initial value)
667