Figure 8-7 illustrates operation in repeat mode.
Address T
Address B
Transfer requests (activation sources) consist of A/D converter conversion end interrupts, external
requests, SCI transmission complete and reception complete interrupts, and TPU channel 0 to 5
compare match/input capture A interrupts. External requests can be set for channel B only.
250
Transfer
Figure 8-7 Operation in Repeat mode
1 byte or word transfer performed in
response to 1 transfer request
Legend
Address T = L
Address B = L + (–1)
Where : L = Value set in MAR
N = Value set in ETCR
DTID
DTSZ
· (2
· (N–1))
IOAR