20.2.3
Module Stop Control Register A and C (MSTPCRA and MSTPCRC)
MSTPCRA
Bit
:
MSTPA7
Initial value
:
R/W
:
MSTPCRC
Bit
:
MSTPC7
Initial value
:
R/W
:
MSTPCRA and MSTPCRC are an 8-bit readable/writable registers that performs module stop
mode control. When the MSTPA2 and MSTPC5 are set to 1, the D/A converter halts and enters
module stop mode at the end of the bus cycle. Register read/write is disenabled in module stop
mode. See section 24.5, Module Stop Mode, for details.
MSTPCRA is initialized to H'3F by a power-on reset and in hardware standby mode. MSTPCRC
is initialized to H'FF by a power-on reset and in hardware standby mode. It is not initialized by a
manual reset and in software standby mode.
774
7
6
MSTPA6
MSTPA5
0
0
R/W
R/W
7
6
MSTPC6
MSTPC5
1
1
R/W
R/W
5
4
MSTPA4
MSTPA3
1
1
R/W
R/W
5
4
MSTPC4
MSTPC3
1
1
R/W
R/W
3
2
MSTPA2
MSTPA1
1
1
R/W
R/W
3
2
MSTPC2
MSTPC1
1
1
R/W
R/W
1
0
MSTPA0
1
1
R/W
R/W
1
0
MSTPC0
1
1
R/W
R/W