SHOW STACK RESILIENCYLINK
Table 5: Parameters in the output of the show stack resiliencylink command
Related
switch provision (stack)
Commands
show stack
stack resiliencylink
switchport resiliencylink
C613-50103-01 REV A
™) C
TACK
OMMANDS
Parameter
Status
Interface

Interface state

Resiliency-link
port(s)
Command Reference for x310 Series
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
Description
The current status of the stack member's resiliency link. Can
be one of:
• Not configured (Master or Member).
• Configured (Master only).
• Successful:
Successfully receiving healthchecks from the Active Master.
• Failed (Member only):
Not receiving any healthchecks from the Active Master.
• Stopped:
The resiliency link is configured, but is inactive. This may
occur in a Disabled Master stack, for example if the
Disabled Master Monitoring feature is not used.
The name of the VLAN interface that is connected to the
resiliency link.
The current status of the interface. Can be either up or
down.
The switch port(s) the resiliency link is connected to.