Lldp Holdtime-Multiplier - Allied Telesis x310-26FT Command Reference Manual

X310 series stackable access switches for alliedware plus version 5.4.6-1.x
Table of Contents

Advertisement

LLDP C
OMMANDS
-
LLDP HOLDTIME
MULTIPLIER

lldp holdtime-multiplier

Overview
This command sets the holdtime multiplier value. The transmit interval is
multiplied by the holdtime multiplier to give the Time To Live (TTL) value that is
advertised to neighbors.
The no variant of this command sets the multiplier back to its default.
Syntax
lldp holdtime-multiplier <2-10>
no lldp holdtime-multiplier
Default
The default holdtime multiplier value is 4.
Mode
Global Configuration
Usage
The Time-To-Live defines the period for which the information advertised to the
neighbor is valid. If the Time-To-Live expires before the neighbor receives another
update of the information, then the neighbor discards the information from its
database.
Examples
To set the holdtime multiplier to 2, use the commands:
awplus#
awplus(config)#
To set the holdtime multiplier back to its default, use the commands:
awplus#
awplus(config)#
Related
show lldp
Commands
C613-50103-01 REV A
Parameter
<2-10>
configure terminal
lldp holdtime-multiplier 2
configure terminal
no lldp holdtime-multiplier 2
Command Reference for x310 Series
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
Description
The multiplier factor.
2319

Advertisement

Table of Contents
loading

This manual is also suitable for:

X310-26fpX310-50fpX310-50ft

Table of Contents