NTP C
OMMANDS

NTP MASTER

ntp master
Overview
Use this command to make the device to be an authoritative NTP server, even if the
system is not synchronized to an outside time source.
Use the no variant of this command to stop the device being the designated NTP
server.
Syntax
ntp master [<stratum>]
no ntp master
Mode
Global Configuration
Usage
The stratum levels define the distance from the reference clock and exist to
prevent cycles in the hierarchy. Stratum 1 is used to indicate time servers, which
are more accurate than Stratum 2 servers. For more information on the Network
Time Protocol go to:
Examples
To stop the device from being the designated NTP server, use the commands:
awplus#
awplus(config)#
To make the device the designated NTP server with stratum number 2, use the
commands:
awplus#
awplus(config)#
C613-50103-01 REV A
Parameter
Description
<stratum>
<1-15> The stratum number defines the configured level that is set
for this master within the NTP hierarchy. The default stratum number
is 12.
www.ntp.org
configure terminal
no ntp master
configure terminal
ntp master 2
Command Reference for x310 Series