openflow version
Overview
Use this command to change the supported OpenFlow version numbers on the
switch. You can specify a list of version numbers.
Use the no variant of this command to change the version number of the
OpenFlow protocol back to the default version 1.3.
Syntax
openflow version <version-list>
no openflow version <version-list>
Default
The OpenFlow version is set to 1.3 by default.
Mode
Global Configuration
Example
To change the OpenFlow protocol version to 1.0 and 1.3:
awplus(config)#
To change the OpenFlow protocol version to the default 1.3:
awplus(config)#
Related
show openflow config
Commands
C613-50103-01 REV A
Parameter
<version-list>
openflow version 1.0 1.3
no openflow version
Command Reference for x310 Series
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
Description
Specifies a list of version numbers separated by a space. The
version numbers are 1.0 and 1.3.