Overview
This command enables the Disabled Master Monitoring (DMM) feature. If a stack
member becomes a disabled master, the DMM feature will use the stack resiliency
link to continue monitoring the health of the separated stack master.
Use the no variant of this command to disable the DMM feature.
Syntax
stack disabled-master-monitoring
no stack disabled-master-monitoring
Default
By default, Disabled Master Monitoring is enabled. However, it only operates if
there is a resiliency link.
Mode
Global Configuration
Usage
This command enables additional stack resiliency link functionality, which is used
if a stack separation occurs. For DMM to operate, a resiliency link must also be
configured
stack member becoming a disabled master, which has the configuration as a
normal stack master except that all its switchports are shutdown.
For more information about the disabled master state, see the
Overview and Configuration
When the DMM feature is enabled, the disabled master will continue to monitor
the health of the original stack master over the stack resiliency link connection. If
the original stack master were to fail, when the DMM feature is enabled, then the
disabled master will detect this and will automatically re-enable its switchports.
This ensures that the stack will continue to pass network traffic, even if a
catastrophic stack failure occurs.
For more information about the DMM feature when the stack member is a disabled
master, see
Examples
To enable the DMM feature, use the following commands:
awplus#
awplus(config)#
To disable the DMM feature, use the following commands:
awplus#
awplus(config)#
Related
switch provision (stack)
Commands
show stack
stack resiliencylink
type stack disabled-master
type stack master-fail
C613-50103-01 REV A
™) C
TACK
OMMANDS
(stack resiliencylink
theVCStack Feature Overview and Configuration
configure terminal
stack disabled-master-monitoring
configure terminal
no stack disabled-master-monitoring
Command Reference for x310 Series
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
command). A stack separation could result in a
Guide.