21. Reassemble the hose (25) from the pump to the "P"
port on the accumulator charge valve (26). Tighten
the hose end securely.
22. Reassemble the hose (27) to the "Drain" port on the
accumulator charge valve (26). Tighten the hose end
securely.
23. Reassemble the hose (28) to the "PIL" port on the
accumulator charge valve (26). Tighten the hose end
securely.
24. Reassemble the hose (29) to the "CF" port on the
accumulator charge valve (26). Tighten the hose end
securely.
25. Reassemble the hose (30) to the "EF" port on the
accumulator charge valve (26). Tighten the hose end
securely.
26. Reassemble the hose (31) to the "LS" port on the
accumulator charge valve (26). Tighten the hose end
securely.
27. Plug the connector (32) from the pressure switch
into the connector on the wire harness. Snap the two
connectors together.
26
32
27
25
28. Place the accumulator bracket (33) with
accumulators (34) against the front side of the
mounting bracket (35) on the hydraulic oil reservoir.
Be sure the branch of the tees point toward the
pump.
Model MMV Rev. 12/04
28
29
V
M C
30
G
L S
S 1
31
MM5150
Transmission: ZF 4 WG-98 TS
29. Insert the two 1/2-13 x 1-1/2" capscrews (36)
through the accumulator bracket (33) and the
mounting bracket on the hydraulic oil reservoir.
Secure in place with two new 1/2-13 elastic locknuts
(37).
30. Reassemble the hoses (38) to the tee under each
accumulator. Tighten all four hoses securely.
34
36
35
31. Replace any tie wraps that were removed.