11.4.8

Electrical Troubleshooting - Free Pivot Mode, Will Not Frame Sway Right

Conditions:
• Ignition ON, engine
running
• Boom angle is
below 40°
• Travel select lever in
[F] FORWARD or
[R] REVERSE
• Park brake OFF
• Service brake
DISENGAGED
11.4.9

Electrical Troubleshooting - Free Pivot Mode, Will Not Frame Sway Left

Conditions:
• Ignition ON, engine
running
• Boom angle is
below 40°
• Travel select lever in
[F] FORWARD or
[R] REVERSE
• Park brake OFF
• Service brake
DISENGAGED
Model MMV Rev. 12/04
With boom below 40° when frame
swaying to the right, the left front tire
comes off the ground.
Check wire and connector to solenoid
12B on Stabil-TRAK™ manifold for
battery voltage.
If OK
Check solenoid coil for correct
resistance (7-9 ohms).
If OK
Remove solenoid cartridge from manifold
and inspect for debris or damage.
If OK
Inspect manifold passages for debris or
obstruction. Clean if necessary.
With boom below 40° when frame
swaying to the left, the right front tire
comes off the ground.
Check wire and connector to solenoid
12A on Stabil-TRAK™ manifold for
battery voltage.
If OK
Check solenoid coil for correct
resistance (7-9 ohms).
If OK
Remove solenoid cartridge from manifold
and inspect for debris or damage.
If OK
Inspect manifold passages for debris or
obstruction. Clean if necessary.
Stabil-TRAK™ System
Not
Repair as necessary.
OK
Not
Replace solenoid coil.
OK
Not
Clean or replace cartridge.
OK
Not
Replace stabilizer cylinder.
OK
Not
Repair as necessary.
OK
Not
Replace solenoid coil.
OK
Not
Clean or replace cartridge.
OK
Not
Replace stabilizer cylinder.
OK