Juniper JUNOSE SOFTWARE FOR E SERIES 11.3.X - LINK LAYER CONFIGURATION GUIDE 2010-10-13 Configuration Manual page 69

Software for e series broadband services routers link layer configuration guide
Table of Contents

Advertisement

Copyright © 2010, Juniper Networks, Inc.
Use the seg-loopback keyword to send the ping to the first segment point (for example,
the next neighbor switch).
Use the destination option to specify the value of the location ID included in the loopback
cell. The location ID is a 16-octet field, and the destination portion is 4 octets. You can
set the location ID to a specific destination or to 0s (zeros) or 1s (ones).
If you set the destination to 0, the loopback location ID in the loopback cell is
initialized to all 0s, and each segment point in the network responds to the ping.
If you set the destination to 1s, the loopback location ID in the loopback cell is
initialized to all 1s, and only the connection endpoint responds to the ping.
If you use the default value of 0xFFFFFFFF, the loopback location ID in the loopback
cell is initialized to all 1s.
For information about how the router handles loopback cells based on location ID, see
Table 6 on page 19.
The count keyword sets the number of OAM loopback cells to send to the destination.
The default value is 5. The maximum is 32.
The timeout keyword sets the amount of time to wait for a response to the sent OAM
loopback cell. The default value is 5 seconds.
The following characters can appear in the display after the ping command has been
issued:
!—Each exclamation point indicates that a reply was received
.—Each period indicates that the ping timed out while waiting for a reply
Example 1—This example generates end-to-end loopback cells for VPI=0 and VCI=105
on ATM interface 2/0. The count value is 5 OAM loopback cells, and the timeout value
is 2 seconds.
host1#ping atm interface atm 2/0 0 105 end-loopback count 5 timeout 2
Sending 5 53-byte OAM end-to-end loopback Echoes timeout is 2 secs
Press Ctrl+c to stop
!!!!!
Success rate = 100% (5/5), round-trip min/avg/max = 0/4/10 ms
Example 2—This example generates segment loopback cells for VPI=0 and VCI=105
on ATM interface 2/0. The destination is set to 0xFFFFFFFF, the count value is 3 OAM
loopback cells, and the timeout value is 1 second.
host1#ping atm interface atm 2/0 0 105 seg-loopback 0xFFFFFFFF count 3 timeout 1
Sending 3 53-byte OAM segment loopback Echoes timeout is 1 secs
Press Ctrl+c to stop
!!!
Success rate = 100% (3/3), round-trip min/avg/max = 0/3/10 ms
There is no no version.
See ping atm interface atm.
Chapter 1: Configuring ATM
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junose 11.3

Table of Contents