atm snmp trap link-status
atm sonet stm-1
atm uni-version
Copyright © 2010, Juniper Networks, Inc.
Use to specify the cable length (line build-out) for the ATM T3 or E3 interface. The
length of cable determines power requirements.
Specify one of the following keywords:
long—A cable length in the range 0–225 feet
short—A cable length in the range 226–450 feet (the default)
Example
host1(config-if)#atm lbo long
Use the no version to restore the default value, short.
See atm lbo.
Use to set an ATM interface administrative state to disabled.
When you set the administrative state of the ATM interface to disabled, the router
automatically disables all F5 OAM services configured on the associated VC, and
prevents the VC from receiving or transmitting F5 OAM cells.
Example
host1(config-if)#atm shutdown
Use the no version to enable a disabled interface.
See atm shutdown.
Use to enable SNMP link status traps on the ATM layer interface.
Example
host1(config-if)#atm snmp trap link-status
Use the no version to disable the traps.
See atm snmp trap link-status.
Use to set the mode of operation on the physical interface to Synchronous Digital
Hierarchy (SDH) Synchronous Transport Mode (STM).
host1(config-if)#atm sonet stm-1
Use the no version to restore the default value, SONET STS-3c operation.
See atm sonet stm-1.
Use to specify the UNI version for the interface to use.
Valid values are 3.0, 3.1, or 4.0.
Example
Chapter 1: Configuring ATM