144
Configured LMI type: one of the following options:
ANSI—ANSI T1.617 Annex D
Q933A—ITU-T Q.933 Annex A
Cisco—Original Group of Four specification developed by DEC, Northern Telecom,
Stratacom, and Cisco
None—Suppresses LMI
status is up—Availability of the MLFR bundle: up or down
Number of interface down transitions—Number of times the interface has become
unavailable
Time since last status change—Elapsed time since LMI information changed
Enquiries received—Total number of LMI status inquiries received by the DCE on
this interface
Enquiry responses sent—Total number of LMI status responses sent by the DCE
on this interface
Full enquiry responses sent—Total number of LMI full status responses sent by
the DCE on this interface
Async updates sent—Total number of LMI ASYNC updates sent by the DCE on
this interface
Unknown messages received—Total number of unknown LMI messages received
on this interface
Loss of sequencing detected—Total number of times a loss of sequencing in
received LMI messages was detected by the DCE on this interface
No response timeouts—Total number of times a timeout occurred without receiving
a status inquiry from the DTE on this interface
Last sequence number sent—Last sequence number sent on this interface
Last sequence number received—last sequence number received on this interface
Example 1
host1#show frame-relay lmi brief
LMI information for frame relay DTE interface mlframe-relayTEST
DTE parameter N391 is 6, N392 is 3, N393 is 4, T391 is 10
Configured LMI type is ANSI, status is up
Number of interface down transitions is 0
Time since last status change 00:05:39
Example 2
host1#show frame-relay lmi interface mlframe-relay TEST
LMI information for frame relay DTE interface mlframe-relayTEST
DTE parameter N391 is 6, N392 is 3, N393 is 4, T391 is 10
Copyright © 2010, Juniper Networks, Inc.