Juniper JUNOSE SOFTWARE FOR E SERIES 11.3.X - LINK LAYER CONFIGURATION GUIDE 2010-10-13 Configuration Manual page 157

Software for e series broadband services routers link layer configuration guide
Table of Contents

Advertisement

show frame-relay map
show frame-relay pvc
Copyright © 2010, Juniper Networks, Inc.
Use to display the current Frame Relay map entries and information about Frame Relay
connections.
Field descriptions
Frame relay sub-interface—Interface number and one of the following states:
Up—Traffic can flow on the interface
Offline—Traffic cannot flow because hardware is unavailable
Down—Traffic cannot flow because of a problem in the interface at the current
protocol layer
LowerLayerDown—Traffic cannot flow because of a problem in an interface at a
lower protocol layer
AdministrativelyDown—Traffic cannot flow because of manual administrative
intervention
DLCI—Provides decimal value, hexadecimal value, and its value as it appears on the
wire
Example
host1#show frame-relay map
Frame relay sub-interface 3/2:1/1.1 (up): DLCI 101(0x65,0x58)
Frame relay sub-interface 3/2:1/1.2 (up): DLCI 102(0x66,0x78)
Frame relay sub-interface 3/2:1/1.3 (up): DLCI 103(0x67,0x78)
Frame relay sub-interface 3/2:1/1.4 (up): DLCI 104(0x68,0x98)
Frame relay sub-interface 3/2:1/1.5 (up): DLCI 105(0x69,0x98)
Frame relay sub-interface 3/2:1/1.6 (up): DLCI 106(0x6a,0xb8)
Frame relay sub-interface 3/2:1/1.7 (up): DLCI 107(0x6b,0xb8)
Frame relay sub-interface 3/2:1/1.8 (up): DLCI 108(0x6c,0xd8)
Frame relay sub-interface 3/2:1/1.9 (up): DLCI 109(0x6d,0xd8)
Frame relay sub-interface 3/2:1/1.10 (up): DLCI 110(0x6e,0xf8)
Frame relay sub-interface 3/2:1/1.11 (up): DLCI 111(0x6f,0xf8)
Frame relay sub-interface 3/2:1/1.12 (up): DLCI 112(0x70,0x1c)
Frame relay sub-interface 3/2:1/1.17 (up): DLCI 117(0x75,0x5c)
Frame relay sub-interface 3/2:1/1.18 (up): DLCI 118(0x76,0x7c)
Frame relay sub-interface 3/2:1/1.19 (up): DLCI 119(0x77,0x7c)
Frame relay sub-interface 3/2:1/1.20 (up): DLCI 120(0x78,0x9c)
Frame relay sub-interface 3/2:1/1.21 (up): DLCI 121(0x79,0x9c)
Frame relay sub-interface 3/2:1/1.22 (up): DLCI 122(0x7a,0xbc)
Frame relay sub-interface 3/2:1/1.23 (up): DLCI 123(0x7b,0xbc)
Frame relay sub-interface 3/2:1/1.24 (up): DLCI 124(0x7c,0xdc)
See show frame-relay map.
Use to display statistics about PVCs for Frame Relay layer on a multilink Frame Relay,
POS, serial, or GRE tunnel interface or a specific PVC.
Optionally, you can specify an interface using the interface type and specifier. For more
information, see Interface Types and Specifiers in JunosE Command Reference Guide.
Chapter 2: Configuring Frame Relay
125

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junose 11.3

Table of Contents