The brief keyword displays abbreviated PVC information.
Field descriptions
DLCI—DLCI number
subinterface—Name and subinterface number of the MLFR bundle in the format
bundle-name.subinterface-number
status—Status of the PVC
Number of circuit status inactive transitions—Number of times a circuit came down
because of error conditions
Time since creation—Time since the PVC was created
last status change—Time since the PVC status last changed
In pkts—Number of incoming packets received on the circuit
Out pkts—Number of outgoing packets transmitted on the circuit
In bytes—Number of input bytes received on the circuit
Out bytes—Number of output bytes received on the circuit
In FECN pkts—Number of packets received with the forward explicit congestion
notification (FECN) bit set. The FECN bit is set by a network to notify the user that
data traffic may experience congestion in the direction of the frame carrying the
FECN bit. The FECN bit is set by the network (not by the transmitting user), and there
is no obligation for end systems to take any action regarding the FECN bit.
Out FECN pkts—Number of packets transmitted with the FECN bit set
In BECN pkts—Number of packets received with the backward explicit congestion
notification (BECN) bit set. The BECN bit is set by a network to notify the user that
data traffic may experience congestion in the opposite direction of the frame carrying
the BECN bit. The BECN bit is set by the network, and there is no obligation for end
systems to take any action regarding the BECN bit.
Out BECN pkts—Number of packets transmitted with the BECN bit set
In DE pkts—Number of packets received with the discard eligibility (DE) bit set. When
the DE bit is set, it indicates that the frame is discarded in preference to other frames
without the DE bit set. The DE bit may be set by the network or the user. Once it is
set, it cannot be reset by the user.
Out DE pkts—Number of packets transmitted with the DE bit set
Dropped packets—Number of dropped packets
Example 1
host1#show frame-relay pvc brief