O4: Maintenance Monitors - YASKAWA GA700 Series Technical Manual

Ac drive for industrial applications
Hide thumbs Also See for GA700 Series:
Table of Contents

Advertisement

No.
Name
(Hex.)
o3-06
Auto Parameter Backup
Selection
(0BDE)
o3-07
Auto Parameter Backup
Interval
(0BDF)

o4: Maintenance Monitors

No.
Name
(Hex.)
o4-01
Elapsed Operating Time
Setting
(050B)
o4-02
Elapsed Operating Time
Selection
(050C)
o4-03
Fan Operation Time
Setting
(050E)
o4-05
Capacitor Maintenance
Setting
(051D)
o4-07
Softcharge Relay
Maintenance Set
(0523)
o4-09
IGBT Maintenance
Setting
(0525)
o4-11
Fault Trace/History Init
(U2/U3)
(0510)
o4-12
kWh Monitor
Initialization
(0512)
o4-13
RUN Command Counter
@ Initialize
(0528)
o4-22
Time Format
(154F)
RUN
o4-23
Date Format
(1550)
RUN
o4-24
bAT Detection Selection
(310F)
RUN
YASKAWA SIEPC71061705H GA700 Series Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that automatically backs up parameters. This parameter is only
available when using an LCD keypad.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the interval at which the automatic parameter backup function saves parameters
from the drive to the keypad.
Note:
This parameter is only available when using an LCD keypad.
0 : Every 10 minutes
1 : Every 30 minutes
2 : Every 60 minutes
3 : Every 12 hours
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the initial value of the cumulative drive operation time in 10-hour units.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the condition that counts the cumulative operation time.
0 : U4-01 Shows Total Power-up Time
1 : U4-01 Shows Total RUN Time
V/f
CL-V/f
OLV
CLV
AOLV
Sets the value from which to start the cumulative drive cooling fan operation time in 10-
hour units.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the U4-05 [CapacitorMaintenance] monitor value.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the U4-06 [PreChargeRelayMainte] monitor value.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the U4-07 [IGBT Maintenance] monitor value.
V/f
CL-V/f
OLV
CLV
AOLV
Resets the records of Monitors U2-xx [Fault Trace] and U3-xx [Fault History].
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Resets the monitor values for U4-10 [kWh, Lower 4 Digits] and U4-11 [kWh, Upper 5
Digits].
0 : No Reset
1 : Reset
V/f
CL-V/f
OLV
CLV
AOLV
Resets the monitor values for U4-02 [Num of Run Commands], U4-24 [Number of Runs
(Low)], and U4-25 [Number of Runs (High)].
0 : No Reset
1 : Reset
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time display format. This parameter is only available when using an LCD
keypad.
0 : 24 Hour Clock
1 : 12 Hour Clock
2 : 12 Hour JP Clock
V/f
CL-V/f
OLV
CLV
AOLV
Sets the date display format. This parameter is only available when using an LCD
keypad.
0 : YYYY/MM/DD
1 : DD/MM/YYYY
2 : MM/DD/YYYY
V/f
CL-V/f
OLV
CLV
AOLV
Sets operation when the drive detects bAT [Keypad Battery Low Voltage] and TiM
[Keypad Time Not Set].
0 : Disable
1 : Enable (Alarm Detected)
2 : Enable (Fault Detected)
11.13 o: Keypad-Related Settings
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
Ref.
(Range)
1
953
(0, 1)
1
953
(0 - 3)
Default
Ref.
(Range)
0 h
953
(0 - 9999 h)
0
954
(0, 1)
0 h
954
(0 - 9999 h)
0%
954
(0 - 150%)
0%
954
(0 - 150%)
0%
954
(0 - 150%)
0
955
(0, 1)
0
955
(0, 1)
0
955
(0, 1)
0
955
(0 - 2)
0
955
(0 - 2)
0
956
(0 - 2)
569
11

Advertisement

Table of Contents
loading

Table of Contents