YASKAWA GA700 Series Technical Manual page 770

Ac drive for industrial applications
Hide thumbs Also See for GA700 Series:
Table of Contents

Advertisement

12.7 F: Options
Terminal
Terminal
Block
Name
[F3-03 = 0]
TB2
D0
1 digit (0 -
9)
D1
D2
D3
D4
2 digits (0 -
*2
15)
D5
D6
D7
TB3
D8
-
D9
DA
DB
DC
-
DD
DE
DF
TB1
SI
SIGN (encoded) signal
0: Forward run, 1: Reverse run
SE
SET (loaded) signal
1: Loads the value set for D0 to DF and SI.
SP
Internal power supply: 24 V ± 5%
SC
Input signal common
SN
Internal power supply common: 0 V
SD
Cable sheath connection terminal (ungrounded)
FE
Cable sheath connection terminal (grounded)
*1
Setting F3-03 = 2 [Digital Input Data Length Select = 16-bit] enables F3-01 = 6 [Digital Input Function Selection = BCD (5-digit),
0.01 Hz] and a frequency between 0.00 Hz to 399.8 Hz can be set by the BCD. Note that terminal SI is also used as for data bits.
Negative commands cannot be input as encoding information (positive/negative) cannot be added to the data.
The minimum bit value for the first BCD digit is 2. For this reason, 0.02 Hz is the smallest setting unit available for this frequency
setting. An oPE05 [Run Cmd/Freq Ref Source Sel Err] occurs when F3-03 ≠ 2 while F3-01 = 6.
*2
The most significant digit can be set to a value between 0 to 15 when using "BCD, Signed". Other digits can be set to a value between
0 to 9.
F3-10: Terminal D0 Function Selection
No.
Name
(Hex.)
F3-10
Terminal D0 Function
Selection
(0BE3)
Expert
F3-11: Terminal D1 Function Selection
No.
Name
(Hex.)
F3-11
Terminal D1 Function
Selection
(0BE4)
Expert
770
Table 12.49 DI-A3 Terminal Function Selection
BCD, Signed
[F3-01 = 0 to 5]
8-bit
12-bit
[F3-03 = 1]
1
1 digit (0 -
1
9)
2
2
4
4
8
8
1
2 digits (0 -
1
9)
2
2
4
4
8
8
-
3 digits (0 -
1
*2
15)
-
2
-
4
-
8
-
-
-
-
-
-
-
-
-
V/f
CL-V/f
OLV
Sets the function for terminal D0 of the DI-A3 option when F3-01 = 8 [Digital Input Function
Selection = Multi-Function Digital Input].
V/f
CL-V/f
OLV
Sets the function for terminal D1 of the DI-A3 option when F3-01 = 8 [Digital Input Function
Selection = Multi-Function Digital Input].
BCD, Unsigned
[F3-01 = 6]
16-bit
[F3-03 = 2]
1 digit (0 -
1
1 digit (0,
9)
2, 4, 6, 8)
2
4
8
2 digits (0 -
9)
2 digits (0 -
1
9)
2
4
8
3 digits (0 -
9)
3 digits (0 -
-
9)
-
-
-
4 digits (0 -
9)
4 digits (0 -
-
*2
15)
-
-
-
5 digits (0 -
3)
Description
CLV
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
CLV
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA SIEPC71061705H GA700 Series Technical Manual
Binary, Signed
*1
[F3-01 = 7]
8-bit
12-bit
[F3-03 =
[F3-03 = 1]
0]
2
bit 0
bit 0
4
bit 1
bit 1
8
bit 2
bit 2
1
bit 3
bit 3
2
bit 4
bit 4
4
bit 5
bit 5
8
bit 6
bit 6
1
bit 7
bit 7
2
-
bit 8
4
-
bit 9
8
-
bit 10
1
-
bit 11
2
-
-
4
-
-
8
-
-
1
-
-
2
SIGN (encoded) signal
0: Forward run, 1: Reverse run
Default
(Range)
(1 - 19F)
Default
(Range)
(1 - 19F)
16-bit
[F3-03 =
2]
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
bit 8
bit 9
bit 10
bit 11
bit 12
bit 13
bit 14
bit 15
F
F

Advertisement

Table of Contents
loading

Table of Contents