YASKAWA GA700 Series Technical Manual page 738

Ac drive for industrial applications
Hide thumbs Also See for GA700 Series:
Table of Contents

Advertisement

12.5 d: References
d7-01: Offset Frequency 1
No.
Name
(Hex.)
d7-01
Offset Frequency 1
(02B2)
RUN
d7-02: Offset Frequency 2
No.
Name
(Hex.)
d7-02
Offset Frequency 2
(02B3)
RUN
d7-03: Offset Frequency 3
No.
Name
(Hex.)
d7-03
Offset Frequency 3
(02B4)
RUN
738
V/f
CL-V/f
OLV
CLV
AOLV
Uses H1-xx = 44 [MFDI Function Select = Add Offset Frequency 1 (d7-01)] as a percentage of
the Maximum Output Frequency to add or subtract the set frequency to/from the frequency
reference.
V/f
CL-V/f
OLV
CLV
AOLV
Uses H1-xx = 45 [MFDI Function Select = Add Offset Frequency 2 (d7-02)] as a percentage of
the Maximum Output Frequency to add or subtract the set frequency to/from the frequency
reference.
V/f
CL-V/f
OLV
CLV
AOLV
Uses H1-xx = 46 [MFDI Function Select = Add Offset Frequency 3 (d7-03)] as a percentage of
the Maximum Output Frequency to add or subtract the set frequency to/from the frequency
reference.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA SIEPC71061705H GA700 Series Technical Manual
Default
(Range)
0.0%
(-100.0 - +100.0%)
Default
(Range)
0.0%
(-100.0 - +100.0%)
Default
(Range)
0.0%
(-100.0 - +100.0%)