F5-07: Terminal M1-M2 Function Select
No.
Name
(Hex.)
F5-07
Terminal M1-M2 Function
Select
(039F)
F5-08: Terminal M3-M4 Function Select
No.
Name
(Hex.)
F5-08
Terminal M3-M4 Function
Select
(03A0)
F5-09: DO-A3 Output Mode Selection
No.
Name
(Hex.)
F5-09
DO-A3 Output Mode
Selection
(03A1)
Refer to
Table 12.50
for more information.
0 : Predefined Individual Outputs
1 : Binary Output
2 : Programmable (F5-01 to F5-08)

F6, F7: Communication Options and Ethernet Options

F6 and F7 parameters are used to set the basic communication settings and method of fault detection for the
communication option card. The communication option card parameters include common option card parameters
and communication protocol-specific parameters.
The following table lists the parameters that need to be set for each communication option card.
Refer to the technical manual for each communication option card for more information on installing, wiring, and
configuring the details needed before starting communication.
WARNING! Sudden Movement Hazard. Do test runs and examine the drive to make sure that the command references are
correct. If you set the command reference incorrectly, it can cause damage to the drive or serious injury or death.
Table 12.52 Correspondence Between Communication Protocols and Parameters (SI-C3, SI-T3, SI-ET3, SI-P3, SI-S3,
CC-Link
Parameter
SI-C3
F6-01 to F6-03
x
F6-04
x
F6-06 to F6-08
x
F6-10, F6-11
x
F6-14
x
F6-16
x
F6-20, F6-21
-
F6-22
-
F6-23 to F6-26
-
F6-30 to F6-32
-
F6-35, F6-36
-
F6-45 to F6-49
-
F6-50 to F6-71
-
F7-01 to F7-15
-
F7-16
-
YASKAWA SIEPC71061705H GA700 Series Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function of terminal M3-M2 on the DO-A3 option. Set F5-09 = 2 [DO-A3 Output Mode
Selection = Programmable (F5-01 to F5-08)] to enable this function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function of terminal M3-M4 on the DO-A3 option. Set F5-09 = 2 [DO-A3 Output Mode
Selection = Programmable (F5-01 to F5-08)] to enable this function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the output mode of signals from the DO-A3 option.
and SI-ES3)
MECHATROLINK-II
MECHATROLINK-III
SI-T3
SI-ET3
x
x
-
-
x
x
-
-
x
x
x
x
x
x
x
-
x
x
-
-
-
-
-
-
-
-
-
-
-
-
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
PROFIBUS-DP
SI-P3
x
-
x
-
x
x
-
-
-
x
-
-
-
-
-
12.7 F: Options
Default
(Range)
F
(0 - 1A7)
Default
(Range)
F
(0 - 1A7)
Default
(Range)
0
(0 - 2)
CANopen
EtherCAT
SI-S3
SI-ES3
x
x
-
-
x
x
-
-
x
x
x
x
-
-
-
-
-
-
-
-
x
-
-
-
-
-
-
-
-
-