O2: Keypad Operation - YASKAWA GA700 Series Technical Manual

Ac drive for industrial applications
Hide thumbs Also See for GA700 Series:
Table of Contents

Advertisement

No.
Name
(Hex.)
o1-48
Trend Plot 1 Scale
Maximum Value
(11C8)
RUN
o1-49
Trend Plot 2 Scale
Minimum Value
(11C9)
RUN
o1-50
Trend Plot 2 Scale
Maximum Value
(11CA)
RUN
o1-51
Trend Plot Time Scale
Setting
(11CB)
RUN
o1-55
Analog Gauge Area
Selection
(11EE)
RUN
o1-56
Analog Gauge Area
Setting
(11EF)
RUN
o1-58
Motor Power Unit
Selection
(3125)

o2: Keypad Operation

No.
Name
(Hex.)
o2-01
LO/RE Key Function
Selection
(0505)
o2-02
STOP Key Function
Selection
(0506)
o2-03
User Parameter Default
Value
(0507)
o2-04
Drive Model (KVA)
Selection
(0508)
o2-05
Home Mode Freq Ref
Entry Mode
(0509)
o2-06
Keypad Disconnect
Detection
(050A)
o2-07
Keypad RUN Direction
@ Power-up
(0527)
YASKAWA SIEPC71061705H GA700 Series Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum value for the vertical axis used to display the monitor that was set in
o1-24 [Custom Monitor 1] as a trend plot. This parameter is only available with an LCD
keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the horizontal axis minimum value used to display the monitor set in o1-25
[Custom Monitor 2] as a trend plot. This parameter is only available with an LCD
keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum value for the vertical axis used to display the monitor that was set in
o1-25 [Custom Monitor 2] as a trend plot. This parameter is only available with an LCD
keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time scale (horizontal axis) to display the trend plot. When you change this
setting, the drive automatically adjusts the data sampling time. This parameter is only
available with an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the range used to display the monitor set in o1-24 [Custom Monitor 1] as an analog
gauge. This parameter is only available with an LCD keypad.
0 : +/- Area ( - o1-56 ~ o1-56 )
1 : + Area ( 0 ~ o1-56 )
V/f
CL-V/f
OLV
CLV
AOLV
Sets the value used to display the monitor set in o1-24 [Custom Monitor 1] as an analog
meter. This parameter is only available with an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the setting unit for parameters that set the motor rated power.
0 : kW
1 : HP
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that lets you use
Modes.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to use
on the keypad to stop the drive when the Run
command source for the drive is REMOTE (external) and not assigned to the keypad.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to keep the settings of changed parameters as user parameter defaults
to use during initialization.
0 : No change
1 : Set defaults
2 : Clear all
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Drive Model code. Set this parameter after replacing the control board.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that makes it necessary to push
frequency reference value while in Drive Mode.
0 : ENTER Key Required
1 : Immediate / MOP-style
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that stops the drive if you disconnect the keypad connection cable
from the drive or if you damage the cable while the keypad is the Run command source.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the direction of motor rotation when the drive is energized and the keypad is the
Run command source.
0 : Forward
1 : Reverse
11.13 o: Keypad-Related Settings
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
to switch between LOCAL and REMOTE
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
to use the keypad to change the
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
Ref.
(Range)
100.0%
947
(-299.9 - +300.0%)
-100.0%
947
(-300.0 - +299.9%)
100.0%
947
(-299.9 - +300.0%)
300 s
947
(1 - 3600 s)
1
947
( 0, 1 )
100.0%
947
(0.0 - 100.0%)
0
947
(0, 1)
Default
Ref.
(Range)
1
948
(0, 1)
1
948
(0, 1)
0
949
(0 - 2)
Determined by the drive
949
(-)
0
950
(0, 1)
0
950
(0, 1)
0
950
(0, 1)
567
11

Advertisement

Table of Contents
loading

Table of Contents