Lcd Display - YASKAWA GA700 Series Technical Manual

Ac drive for industrial applications
Hide thumbs Also See for GA700 Series:
Table of Contents

Advertisement

4.2 Keypad Components and Functions
Symbol
Name
LO/RE Selection Key
F
STOP Key
G
Left Arrow Key
Up Arrow Key/Down
Arrow Key
/
H
Right Arrow Key (RESET)
ENTER Key
RUN Key
I
J
USB Terminal
K
RJ-45 Connector
L
Clock Battery Cover
M
Nameplate
*1
Refer to
Replace the Keypad Battery on page 418
WARNING! Sudden Movement Hazard. If you change the control source when b1-07 = 1 [LOCAL/REMOTE Run Selection =
Accept Existing RUN Command], the drive can start suddenly. Before you change the control source, remove all personnel from
the area around the drive, motor, and load. Sudden starts can cause serious injury or death.

LCD Display

136
Switches drive control for the Run command and frequency reference between the keypad (LOCAL) and an external source
(REMOTE).
Note:
• The LOCAL/REMOTE Selection Key continuously stays enabled after the drive stops in Drive Mode. If the application must not
switch from REMOTE to LOCAL because it will have a negative effect on system performance, set o2-01 = 0 [LO/RE Key
Function Selection = Disabled] to disable
• The drive will not switch between LOCAL and REMOTE when it is receiving a Run command from an external source.
Stops drive operation.
Note:
Push
to stop the motor. This will also apply when a Run command (REMOTE Mode) is active at an external Run command
source. To disable
priority, set o2-02 = 0 [STOP Key Function Selection = Disabled].
• Moves the cursor to the left.
• Goes back to the previous screen.
• Scrolls up or down to show the next item or the previous item.
• Selects parameter numbers, and increments or decrements setting values.
• Moves the cursor to the right.
• Continues to the next screen.
• Resets the drive to clear a fault.
• Enters parameter values and settings.
• Selects menu items to move between keypad displays.
• Selects each mode, parameter, and set value.
Starts the drive in LOCAL Mode.
Starts the operation in Auto-Tuning Mode.
Note:
Before you use the keypad to operate the motor, push
For factory adjustment
Connects to the drive using an RJ-45 8-pin straight through UTP CAT5e extension cable or keypad connector.
Remove this cover to install or replace the clock battery.
Note:
You must supply the clock battery
Shows the model number of the keypad and other information
Note:
• "REV" identifies the hardware and software version of the keypad.
• "FLASH" identifies the version of the flash memory.
for information about the correct clock battery and the installation procedure.
Figure 4.2 LCD Display Indications
Function
.
on the keypad to set the drive to LOCAL Mode.
*1
. It is not included with the keypad.