YASKAWA GA700 Series Technical Manual page 765

Ac drive for industrial applications
Hide thumbs Also See for GA700 Series:
Table of Contents

Advertisement

F1-35: Encoder 2 Pulse Monitor Scaling
No.
Name
(Hex.)
F1-35
Encoder 2 Pulse Monitor
Scaling
(03BE)
When the setting value is a 3-digit value (xyz), the dividing ratio is (1 + x)/yz.
For example, when F1-35 = 032, the dividing ratio is 1/32.
Note:
For a single-pulse encoder, the dividing ratio for the monitor signal is 1:1.
F1-36: Encoder 2 PCB Disconnect Detect
No.
Name
(Hex.)
F1-36
Encoder 2 PCB Disconnect
Detect
(03B5)
0 : Disabled
1 : Enabled
F1-37: Encoder 2 Signal Selection
No.
Name
(Hex.)
F1-37
Encoder 2 Signal Selection
(03BD)
0 : A Pulse Detection
1 : AB Pulse Detection
F1-46: dv2 Detection Method Selection
No.
Name
(Hex.)
F1-46
dv2 Detection Method
Selection
(1B98)
To detect dv2 while a multi-pole motor (for example 24 or more poles) is running at zero speed, set F1-46 = 1
[MechanicalAngle Detection Method].
0 : ElectricalAngle Detection Method
1 : MechanicalAngle Detection Method
F1-47: Deviation 2 Detection Selection
No.
Name
(Hex.)
F1-47
Deviation 2 Detection
Selection
(1B99)
These F1-46 [dv2 Detection Method Selection] settings change the setting units of F1-47:
• F1-46 = 0: F1-47 uses electric angles (deg)
• F1-46 = 1: F1-47 uses mechanical angles (one motor rotation is equivalent to a mechanical angle of 360
degrees)
F1-50: PG-F3 Option Encoder Type
No.
Name
(Hex.)
F1-50
PG-F3 Option Encoder
Type
(03D2)
YASKAWA SIEPC71061705H GA700 Series Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the ratio between the pulse input and the pulse output of the encoder as a 3-digit number for
motor 2. The first digit is the numerator and the second and third digits set the denominator.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that enables and disables detection of a disconnected encoder connection cable
to cause PGoH [Encoder (PG) Hardware Fault] for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of channels for the signal to the encoder option card for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Usually it is not necessary to change this setting. Sets the detection method for dv2 [Z Pulse Noise
Fault Detection].
V/f
CL-V/f
OLV
CLV
AOLV
Usually it is not necessary to change this setting. Sets the sensitivity of detection for dv2 [Z Pulse
Noise Fault Detection]. Increase the value to decrease the sensitivity.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the type of encoder connected to the PG-F3 option.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
12.7 F: Options
Default
(Range)
001
(001 - 032, 102 - 132 (1 - 1/
32))
Default
(Range)
1
(0, 1)
Default
(Range)
0
(0, 1)
Default
(Range)
0
(0, 1)
Default
(Range)
15°
(0 - 180°)
Default
(Range)
0
(0 - 2)
12
765

Advertisement

Table of Contents
loading

Table of Contents