YASKAWA GA700 Series Technical Manual page 415

Ac drive for industrial applications
Hide thumbs Also See for GA700 Series:
Table of Contents

Advertisement

Screw Size
Screw Shape
M6
M8
M10
*1
When wiring drive models 2056, 4089, and smaller, select the correct tools for the wire gauge.
*2
Use 6.35 mm (0.25 in) bit socket holder.
*3
Use a torque wrench that can apply this torque measurement range.
Remove the Control Circuit Terminal Block
Remove the keypad and the drive front cover before doing these steps.
1.
Loosen the screws on the control circuit terminal block.
2.
Slide the wired control circuit terminal block down and remove it.
Wire a New Drive
Remove the keypad, front cover, and control circuit terminal block of the new drive. Wire the drive to the main
circuit terminal block before you install a wired control circuit terminal block.
1.
Pull the wiring cover away from the drive to remove it.
A - Wiring cover
YASKAWA SIEPC71061705H GA700 Series Technical Manual
Adapter
Model
Bit
SF-BIT-HEX 5-50
Bit
SF-BIT-SL 1,2X6,5-70 PHOENIX CONTACT
Bit
SF-BIT-HEX 6-50
Bit
SF-BIT-HEX 8-50
Figure 8.70 Loosen the Screws
Figure 8.71 Remove the Control Circuit Terminal Block
A
B
Figure 8.72 Remove the Wiring Cover
Bit
Torque Driver Model
(Tightening Torque)
Manufacturer
PHOENIX CONTACT
PHOENIX CONTACT
PHOENIX CONTACT
B - Main circuit terminal block
8.5 Replace the Drive
Torque Wrench
5 - 9 N∙m
*2
-
(44.3 - 79.9 lbf∙in)
*3
3 - 3.5 N∙m
*2
-
(26.6 - 31.0 lbf∙in)
*3
8 - 12 N∙m
*2
-
(70.8 - 106.2 lbf∙in)
*3
12 - 14 N∙m
*2
-
(106.2 - 123.9 lbf∙in)
*3
415