CAUTION! Burn Hazard. Do not touch a hot drive heatsink. De-energize the drive, wait for a minimum of 15 minutes, then make
sure that the heatsink is cool before you replace the cooling fans. If you touch a hot drive heatsink, it can burn you.
NOTICE: Use the instructions in this manual to replace the cooling fans. When you do maintenance on the fans, replace all the
fans to increase product life. If you install the fans incorrectly, it can cause damage to the drive.
Fan Removal
1.
Remove the drive cover.
CAUTION! Crush Hazard. Loosen the cover screws. Do not fully remove them. If you fully remove the cover screws,
the terminal cover can fall and cause moderate injury.
2.
Unplug the fan cable from the fan connectors.
A - Fan unit
B - Fan connectors
3.
Loosen the screws that safety the fan unit and slide the slide panel to the left.
Note:
To remove the fan unit, it is only necessary to loosen the screws in position B.
Remove the screws in position A.
A - Screw position A
B - Screw position B
YASKAWA SIEPC71061705H GA700 Series Technical Manual
8.4 Replace Cooling Fans and Circulation Fans
C - Fan cable
Figure 8.49 Remove the Fan Cable
C - Slide panel
Figure 8.50 Slide the Slide Panel