YASKAWA GA700 Series Technical Manual page 439

Ac drive for industrial applications
Hide thumbs Also See for GA700 Series:
Table of Contents

Advertisement

Item
Electronic circuit protection
Note:
Ground Fault
This protection detects ground faults during run. The drive will not provide protection when:
Protection
• There is a low-resistance ground fault for the motor cable or terminal block
• Energizing the drive when there is a ground fault.
DC Bus Charge LED Charge LED illuminates when DC bus voltage is more than 50 V.
Item
Indoors
Area of Use
Overvoltage Category III
Power supply
IP20/UL Open Type: -10°C to +50 °C (14 °F to 122 °F)
IP20/UL Type 1: -10 °C to +40 °C (14 °F to 104 °F)
• When you install the drive in an enclosure, use a cooling fan or air conditioner to keep the internal air temperature in the permitted range.
Ambient
Temperature Setting
• Do not let the drive freeze.
• You can use IP20/UL Open Type drives at a maximum of 60 °C (140 °F) when you derate the output current.
• You can use IP20/UL Type 1 drives at a maximum of 50 °C (122 °F) when you derate the output current.
95% RH or less
Humidity
Do not let condensation form on the drive.
Storage Temperature -20 °C to +70 °C (-4 °F to +158 °F) (short-term temperature during transportation)
Pollution degree 2 or less
Install the drive in an area without:
• Oil mist, corrosive or flammable gas, or dust
• Metal powder, oil, water, or other unwanted materials
Surrounding Area
• Radioactive materials or flammable materials, including wood
• Harmful gas or fluids
• Salt
• Direct sunlight
1000 m (3281 ft) Maximum
Note:
Derate the output current by 1% for each 100 m (328 ft) to install the drive in altitudes between 1000 m to 4000 m (3281 ft to 13123 ft).
Altitude
It is not necessary to derate the rated voltage in these conditions:
• Installing the drive at 2000 m (6562 ft) or lower
• Installing the drive between 2000 m to 4000 m (6562 ft to 13123 ft) and grounding the neutral point on the power supply.
Contact Yaskawa or your nearest sales representative if you will not ground the neutral point.
• 10 Hz to 20 Hz: 1 G (9.8 m/s
• 20 Hz to 55 Hz:
Vibration
2004 to 2211, 4002 to 4168: 0.6 G (5.9 m/s
2257 to 2415, 4208 to 4675: 0.2 G (2.0 m/s
Installation
Install the drive vertically for sufficient airflow to cool the drive.
Orientation
Item
• UL61800-5-1
• EN61800-3
Harmonized Standard
• IEC/EN61800-5-1
• Two Safe Disable inputs and one EDM output according to EN ISO 13849-1:2015 (PL e (Cat.III)), IEC/EN61508 SIL3
IP20/UL Open Type
IP20/UL Type 1
Enclosure Protection
Design
Note:
To change an IP20/UL Open Type drive to an IP20/UL Type 1 drive, install a UL Type 1 kit.
YASKAWA SIEPC71061705H GA700 Series Technical Manual
Specification
Table 10.11 Environment
Specification
2
2
, 32.15 ft/s
)
2
2
, 19.36 ft/s
)
2
, 6.56 ft/s
2
)
Table 10.12 Standard
Specification
10.5 Drive Specifications
439
10