12.11 o: Keypad-Related Settings
No.
Item
*2
5
Monitor Unit 1
6
Monitor number 2
7
Monitor Unit 2
:
:
22
Monitor number 10
23
Monitor Unit 10
24 - 27
Reserved
28
Row number
*1
If there is no data log monitor selected, the text string of [0000] is generated.
*2
Refer to
Table 12.82
for information about unit codes.
Unit Code (Hex.)
Unit
00
01
Hz
02
RPM
03
%
04
VAC
05
VDC
06
A
07
sec
Third and Subsequent Rows: Log Data
This example shows the data text strings and data generated for the third row of log data.
Example of generated data:
02,0012,160107111239,1770,1770,00BE,0118,0028,0000,0000,0000,0000,0000,0000,0000,00000C
No.
Item
1
Attribute
2
File number
3
Time stamp
4
Log Monitor Data 1
5
Log Monitor Data 2
:
:
13
Log Monitor Data 10
14
Reserved
15
Encoding data
16
Row number
o5-01: Log Start/Stop Selection
No.
Name
(Hex.)
o5-01
Log Start/Stop Selection
(1551)
RUN
0 : OFF
958
Number of
Characters
4
Unit code and number of decimal places used for the monitor selected with o5-03
Example when U1-01 = 30.00 Hz:
Number of decimal places = 2, Hz unit code = 01, monitor unit 1 = 0201 (Hex.)
4
Monitor number (Dec.) set to o5-04 [Log Monitor Data10]
4
Unit code and number of decimal places used for the monitor selected with o5-04
:
:
4
Monitor number (Dec.) set to o5-12 [Log Monitor Data10]
4
Unit code and number of decimal places used for the monitor selected with o5-12
4
-
6
Row number (Hex.) in the data log file
Table 12.82 Unit Codes
Unit Code (Hex.)
Unit
08
PPR
09
kW
0A
Ω
0B
ms
0C
kHz
0D
PSI
0E
MPM
0F
FPM
Number of
Characters
2
[02] shows that the record is a monitor data record.
4
Generates the [xxx] part (a 3-digit decimal number) of the [GLOG0xxx.csv] filename of the log data in hexadecimal
format.
12
Data log data was retrieved (YYMMDDHHMMSS)
4
Log monitor data (Hex.) of the monitor selected with o5-03 [Log Monitor Data 1]
4
Log monitor data (Hex.) of the monitor selected with o5-04 [Log Monitor Data 2]
:
:
4
Log monitor data (Hex.) of the monitor selected with o5-12 [Log Monitor Data 10]
4
-
4
Log Monitor Data 1 to 10 Code Data (Hex.)
Bits 0 to 9 show the encoding of log monitor data 1 to 10. A bit value of 1 shows that the data represents a negative
value. (Log monitor data 1 to 10 are absolute value data without encoding)
Example when log monitor data 2, 5, and 8 show negative values: Bits 1, 4, and 7 have values of 1, and the encoding
data = 0010010010 (Bin.) = 0092 (Hex.)
6
Row number (Hex.) in the data log file
V/f
CL-V/f
OLV
CLV
Sets the data log function. This parameter is only available when using an LCD keypad.
Description
Unit Code (Hex.)
Unit
10
H
11
V
12
us
13
min
14
°C
15
W
16
kWH
17
MWH