11.12 n: Special Adjustment

n8: PM Motor Control Tuning

No.
Name
(Hex.)
n8-01
Pole Position Detection
Current
(0540)
Expert
n8-02
Pole Alignment Current
Level
(0541)
Expert
n8-03
Pole Position Detection
Time
(0542)
n8-04
Pole Alignment Time
(0543)
Expert
n8-11
Observer Calculation
Gain 2
(054A)
n8-14
Polarity Compensation
Gain 3
(054D)
Expert
n8-15
Polarity Compensation
Gain 4
(054E)
Expert
n8-21
Motor Back-EMF (Ke)
Gain
(0554)
Expert
n8-35
Initial Pole Detection
Method
(0562)
n8-36
HFI Frequency Level for
L Tuning
(0563)
n8-37
HFI Voltage Amplitude
Level
(0564)
Expert
n8-39
HFI LPF Cutoff Freq
(0566)
n8-41
HFI P Gain
(0568)
Expert
n8-42
HFI I Time
(0569)
Expert
562
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Initial Rotor Position Estimated Current as a percentage where E5-03 [PM
Motor Rated Current (FLA)] = 100%. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the current at the time of polar attraction as a percentage where E5-03 [PM Motor
Rated Current (FLA)] = 100%. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of the Current Starting Time, which is used for Z Pulse Offset Tuning.
Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of the Polar Attraction Time, which is used for Z Pulse Offset Tuning.
Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets how the drive detects the position of the rotor at start.
Note:
• When you operate an SPM motor, set n8-35 = 0. When you operate an IPM motor,
you can set n8-35 = 0 to 2.
• When you set n8-35 = 1, doHigh Frequency Injection Auto-Tuning.
0 : Pull-in
1 : High Frequency Injection
2 : Pulse Injection
V/f
CL-V/f
OLV
CLV
AOLV
Sets the injection frequency for high frequency injection.
Note:
• Set n8-35 = 1 [Initial Pole Detection Method = High Frequency Injection] or n8-
57 = 1 [HFI Overlap Selection = Enabled] to enable this parameter.
• The drive automatically calculates this value when High Frequency Injection
Auto-Tuning completes successfully.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the high frequency injection amplitude as a percentage where 200 V = 100% for
200 V class drives and 400 V = 100% for a 400 V class drives. Usually it is not
necessary to change this setting.
Note:
• Set n8-35 = 1 [Initial Pole Detection Method = High Frequency Injection] or n8-
57 = 1 [HFI Overlap Selection = Enabled] to enable this parameter.
• The drive automatically calculates this value when High Frequency Injection
Auto-Tuning completes successfully.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the low-pass filter shut-off frequency for high frequency injection.
Note:
• Set n8-35 = 1 [Initial Pole Detection Method = High Frequency Injection] or n8-
57 = 1 [HFI Overlap Selection = Enabled] to enable this parameter.
• The drive automatically calculates this value when High Frequency Injection
Auto-Tuning completes successfully.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the response gain for the high frequency injection speed estimation.
Note:
• Set n8-35 = 1 [Initial Pole Detection Method = High Frequency Injection] or n8-
57 = 1 [HFI Overlap Selection = Enabled] to enable this parameter.
• When A1-02= 6 [Control Method Selection = AOLV/PM] and you do High
Frequency Injection Auto-Tuning, the drive automatically sets this parameter .
V/f
CL-V/f
OLV
CLV
AOLV
Sets the integral time constant for the high frequency injection speed estimation.
Usually it is not necessary to change this setting.
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA SIEPC71061705H GA700 Series Technical Manual
Default
Ref.
(Range)
50%
933
(0 - 100%)
80%
933
(0 - 150%)
1.5 s
933
(1.5 - 5.0 s)
1.5 s
933
(1.5 - 5.0 s)
Determined by n8-72
933
(0.0 - 1000.0)
1.000
934
(0.000 - 10.000)
0.500
934
(0.000 - 10.000)
0.90
934
(0.80 - 1.00)
Determined by A1-02
934
(0 - 2)
500 Hz
934
(200 - 1000 Hz)
20.0%
935
(0.0 - 50.0%)
250 Hz
935
(0 - 1000 Hz)
2.5
935
(-10.0 - +10.0)
0.10 s
935
(0.00 - 9.99 s)

Advertisement