YASKAWA GA700 Series Technical Manual page 964

Ac drive for industrial applications
Hide thumbs Also See for GA700 Series:
Table of Contents

Advertisement

12.12 T: Auto-Tuning
T1-07: Motor Base Speed
No.
Name
(Hex.)
T1-07
Motor Base Speed
(0707)
T1-08: Encoder Pulse Count (PPR)
No.
Name
(Hex.)
T1-08
Encoder Pulse Count (PPR)
(0708)
Set the actual number of pulses for one full motor rotation.
T1-09: Motor No-Load Current
No.
Name
(Hex.)
T1-09
Motor No-Load Current
(0709)
Note:
The display units are different for different models:
• 2004 - 2042, 4002 - 4023: 0.01 A
• 2056 - 2415, 4031 - 4675: 0.1 A
The value shown is the no-load current that the drive automatically calculates from the values set in T1-02 [Motor
Rated Power] and T1-04 [Motor Rated Current]. Set the no-load current shown on the motor test report. If the
motor test report is not available, do not change this parameter.
T1-10: Motor Rated Slip Frequency
No.
Name
(Hex.)
T1-10
Motor Rated Slip
Frequency
(070A)
Shows 0.000 Hz as the default value. Set the rated slip shown on the motor test report. If the motor test report is
not available, do not change this parameter.
T1-11: Motor Iron Loss
No.
Name
(Hex.)
T1-11
Motor Iron Loss
(070B)
Note:
The default setting is different for different motor codes and motor parameter settings.
The value shown is the E2-10 [Motor Iron Loss] or E4-10 [Motor 2 Iron Loss] for the motor output set in T1-02
[Motor Rated Power]. If the motor test report is available, enter the motor iron loss value to T1-11.
T1-12: Test Mode Selection
No.
Name
(Hex.)
T1-12
Test Mode Selection
(0BDB)
0 : No
1 : Yes
After Auto-Tuning, the drive automatically sets E2-02 [Motor Rated Slip] and E2-03 [Motor No-Load Current]
when you operate the motor for the first time in Drive Mode.
964
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor base speed for Auto-Tuning (min
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of PG (pulse generator, encoder) pulses.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the no-load current of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets motor rated slip.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the iron loss for calculating the energy-saving coefficient.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to enable Test Mode after Stationary Auto-Tuning. When you can operate the
motor with a light load attached after Stationary Auto-Tuning is complete, enable this parameter.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
-1
(r/min)).
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA SIEPC71061705H GA700 Series Technical Manual
Default
(Range)
-1
1450 min
(r/min)
-1
(0 - 35400 min
(r/min))
Default
(Range)
1024 ppr
(0 - 60,000 ppr)
Default
(Range)
-
(0 A - T1-04; max. of
2999.9)
Default
(Range)
-
(0.000 - 20.000 Hz)
Default
(Range)
Determined by E2-11 or
E4-11
(0 - 65535 W)
Default
(Range)
0
(0, 1)

Advertisement

Table of Contents
loading