YASKAWA GA700 Series Technical Manual page 563

Ac drive for industrial applications
Hide thumbs Also See for GA700 Series:
Table of Contents

Advertisement

No.
Name
(Hex.)
n8-45
Speed Feedback
Detection Gain
(0538)
n8-47
Pull-in Current Comp
Filter Time
(053A)
n8-48
Pull-in/Light Load Id
Current
(053B)
n8-49
Heavy Load Id Current
(053C)
Expert
n8-51
Pull-in Current @
Acceleration
(053E)
n8-54
Voltage Error
Compensation Time
(056D)
Expert
n8-55
Motor to Load Inertia
Ratio
(056E)
n8-57
HFI Overlap Selection
(0574)
n8-62
Output Voltage Limit
Level
(057D)
Expert
n8-65
Speed Fdbk Gain @ oV
Suppression
(065C)
Expert
n8-69
Speed Observer Control
P Gain
(065D)
Expert
n8-72
Speed Estimation
Method Select
(0655)
Expert
n8-74
Light Load Iq Level
(05C3)
Expert
n8-75
Medium Load Iq Level
(low)
(05C4)
Expert
n8-77
Heavy Load Iq Level
(05CE)
Expert
n8-78
Medium Load Id Current
(05F4)
Expert
YASKAWA SIEPC71061705H GA700 Series Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the internal speed feedback detection reduction unit gain as a magnification value.
Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time constant the drive uses to align the pull-in current reference value with the
actual current value. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the d-axis current that flows to the motor during run at constant speed as a
percentage where E5-03 [PM Motor Rated Current (FLA)] = 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the d-axis current to that the drive will supply to the motor to run it at a constant
speed with a heavy load. Considers E5-03 [PM Motor Rated Current (FLA)] to be
100%. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the pull-in current allowed to flow during acceleration/deceleration as a percentage
of the motor rated current.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the motor
rated current.
• A1-02 = 5 [OLV/PM]: E5-03 [PM Motor Rated Current (FLA)]
• A1-02 = 8 [EZOLV]: E9-06 [Motor Rated Current (FLA)]
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time constant that the drive uses when adjusting for voltage errors.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the ratio between motor inertia and machine inertia.
0 : Below 1:10
1 : Between 1:10 and 1:30
2 : Between 1:30 and 1:50
3 : Beyond 1:50
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that detects motor speed with high frequency injection.
Note:
When you set n8-57 = 1, do High Frequency Injection Auto-Tuning.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the output voltage limit to prevent saturation of the output voltage. Usually it is not
necessary to change this parameter.
Note:
• When A1-02 = 7, 8 [Control Method Selection = CLV/PM EZOLV], this
parameter is available in Expert mode.
• 200 V Class: 230.0 V
• 400 V Class: 460.0 V
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain of internal speed feedback detection suppression while the overvoltage
suppression function is operating as a magnification value. Usually it is not necessary to
change this parameter.
V/f
CL-V/f
OLV
CLV
AOLV
Usually it is not necessary to change this setting. Sets the Proportional gain that the
drive uses for speed estimation.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the speed estimation method. Usually it is not necessary to change this setting.
0 : Method 1
1 : Method 2
V/f
CL-V/f
OLV
CLV
AOLV
Set n8-48 [Pull-in/Light Load Id Current] to the percentage of load current (q-axis
current) that you will apply, where E5-03 [PM Motor Rated Current (FLA)] = a setting
value of 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Set n8-78 [Medium Load Id Current] to the percentage of load current (q-axis current)
that you will apply, where E5-03 [PM Motor Rated Current (FLA)] = a setting value of
100%.
V/f
CL-V/f
OLV
CLV
AOLV
Set n8-49 [Heavy Load Id Current] to the percentage of load current (q-axis current)
that you will apply, where E5-03 [PM Motor Rated Current (FLA)] = a setting value of
100%.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the level of the pull-in current for mid-range loads.
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.12 n: Special Adjustment
Default
Ref.
(Range)
0.80
935
(0.00 - 10.00)
5.0 s
936
(0.0 - 100.0 s)
30%
936
(20 - 200%)
Determined by E5-01
936
(-200.0 - 0.0%)
Determined by A1-02
936
(0 - 200%)
1.00 s
936
(0.00 - 10.00 s)
0
937
(0 - 3)
0
937
(0, 1)
200 V Class: 200.0 V,
938
400 V Class: 400.0 V
(200 V Class: 0.0 to
230.0 V, 400 V Class:
0.0 to 460.0 V)
1.50
938
(0.00 - 10.00)
1.00
938
(0.00 - 20.00)
1
938
(0, 1)
30%
938
(0 - 255%)
50%
939
(0 - 255%)
90%
939
(0 - 255%)
0%
939
(0 - 255%)
11
563