YASKAWA GA700 Series Technical Manual page 762

Ac drive for industrial applications
Hide thumbs Also See for GA700 Series:
Table of Contents

Advertisement

12.7 F: Options
F1-09: Overspeed Detection Delay Time
No.
Name
(Hex.)
F1-09
Overspeed Detection Delay
Time
(0388)
When the motor speed is more than the value set in F1-08 [Overspeed Detection Level] for longer than the time
set in F1-09, the drive will detect oS.
F1-10: Speed Deviation Detection Level
No.
Name
(Hex.)
F1-10
Speed Deviation Detection
Level
(0389)
When the speed deviation between the frequency reference and the actual motor speed is more than the value set
in F1-10 for longer than the time set in F1-11 [Speed Deviation Detect DelayTime], the drive will detect dEv.
F1-11: Speed Deviation Detect DelayTime
No.
Name
(Hex.)
F1-11
Speed Deviation Detect
DelayTime
(038A)
When the speed deviation between the frequency reference and the actual motor speed is more than the value set
in F1-10 [Speed Deviation Detection Level] for longer than the time set in F1-11, the drive will detect dEv.
F1-12: Encoder 1 Gear Teeth 1
No.
Name
(Hex.)
F1-12
Encoder 1 Gear Teeth 1
(038B)
After you set the number of gear teeth, the drive uses this formula to calculate the motor speed:
Note:
When F1-12 = 0 or F1-13 = 0, the gear ratio is 1.
F1-13: Encoder 1 Gear Teeth 2
No.
Name
(Hex.)
F1-13
Encoder 2 Gear Teeth 1
(038C)
After you set the number of gear teeth, the drive uses this formula to calculate the motor speed:
Note:
When F1-12 = 0 or F1-13 = 0, the gear ratio is 1.
F1-14: Encoder Open-Circuit Detect Time
No.
Name
(Hex.)
F1-14
Encoder Open-Circuit
Detect Time
(038D)
762
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of time that the speed feedback must be more than the F1-08 level to cause oS
[Overspeed].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the detection level of dEv [Speed Deviation] as a percentage when the maximum output
frequency is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of time that the difference between the frequency reference and speed feedback
must be more than the level in F1-10 to cause dEv [Speed Deviation].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of gear teeth on the motor side. This parameter and F1-13 [Encoder 1 Gear Teeth
2] set the gear ratio between the motor and encoder.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of gear teeth on the load side. This parameter and F1-12 [Encoder 1 Gear Teeth
1] set the gear ratio between the motor and encoder.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of time that the drive must not receive a pulse signal to cause PGo [Encoder (PG)
Feedback Loss].
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA SIEPC71061705H GA700 Series Technical Manual
Default
(Range)
Determined by A1-02
(0.0 - 2.0 s)
Default
(Range)
10%
(0 - 50%)
Default
(Range)
0.5 s
(0.0 - 10.0 s)
Default
(Range)
0
(0 - 1000)
Default
(Range)
0
(0 - 1000)
Default
(Range)
2.0 s
(0.0 - 10.0 s)