YASKAWA GA700 Series Technical Manual page 631

Ac drive for industrial applications
Hide thumbs Also See for GA700 Series:
Table of Contents

Advertisement

7 : Crane (Traveling)
The drive automatically sets the parameters in
No.
A1-02
b1-01
C1-01
C1-02
C6-01
C6-02
d1-01
d1-02
d1-03
H1-05
H1-06
H2-01
H2-02
H3-06
L3-04
L8-05
L8-07
L8-38
L8-41
The drive saves the parameters in
Table 12.17 Parameters Saved as User Parameters with the Traveling Preset
User Parameter No.
A2-01
A2-02
A2-03
A2-04
A2-05
A2-06
A2-07
A2-08
A2-09
A2-10
A2-11
A2-12
Notes for Elevator Applications
When you use the drive for elevator applications, read the safety descriptions and precautions, and safely and
correctly use the device.
Conditions to Open and Close the Brake
Set L4-07 = 0 [Speed Agree Detection Selection = No Detection during Baseblock] to open and close the holding
brake.
When L4-07 = 1 [Detection Always Enabled], the output frequency increases when you input the Run command
although the external baseblock command is input. Because of this, speed detection operates and will open the
brake signal.
YASKAWA SIEPC71061705H GA700 Series Technical Manual
Table 12.16
Table 12.16 Optimal Settings for Traveling Applications
Name
Control method selection
Frequency Reference Selection 1
Acceleration Time 1
Deceleration Time 1
Normal / Heavy Duty Selection
Carrier Frequency Selection
Reference 1
Reference 2
Reference 3
Terminal S5 Function Selection
Terminal S6 Function Selection
Terminal M1-M2 Function Selection
Terminal M3-M4 Function Selection
Terminal A3 Function Selection
Stall Prevention during Decel
Input Phase Loss Protection Sel
Output Phase Loss Protection Sel
Carrier Frequency Reduction
High Current Alarm Selection
Table 12.17
as user parameters.
Parameter No. Saved
b1-01
C1-01
C1-02
C6-02
d1-01
d1-02
d1-03
E2-01
H1-05
H1-06
H2-01
L1-01
12.2 A: Initialization Parameters
for a traveling application.
Terminal M1-M2 Function Selection
Optimal Value
0: V/f Control
0: Keypad
3.0 s
3.0 s
0: Heavy Duty Rating
2: 5 kHz
6.00 Hz
30.00 Hz
50.00 Hz
3: Multi-Step Speed Reference 1
4: Multi-Step Speed Reference 2
37: During Frequency Output
37: During Frequency Output
1F: Not Used
0: Disabled
1: Enabled
1: Fault when one phase is lost
1: Enabled below 6 Hz
1: Enabled
Name
Frequency Reference Selection 1
Acceleration Time 1
Deceleration Time 1
Carrier Frequency Selection
Reference 1
Reference 2
Reference 3
Motor Rated Current (FLA)
Terminal S5 Function Selection
Terminal S6 Function Selection
Motor Overload (oL1) Protection
12
631