N3: High Slip/Overexcite Braking; N4: Adv Open Loop Vector Tune - YASKAWA GA700 Series Technical Manual

Ac drive for industrial applications
Hide thumbs Also See for GA700 Series:
Table of Contents

Advertisement

n3: High Slip/Overexcite Braking

No.
Name
(Hex.)
n3-01
HSB Deceleration
Frequency Width
(0588)
Expert
n3-02
HSB Current Limit
Level
(0589)
Expert
n3-03
HSB Dwell Time at Stop
(058A)
Expert
n3-04
HSB Overload Time
(058B)
Expert
n3-13
OverexcitationBraking
(OEB) Gain
(0531)
n3-14
OEB High Frequency
Injection
(0532)
Expert
n3-21
HSB Current
Suppression Level
(0579)
n3-23
Overexcitation Braking
Operation
(057B)

n4: Adv Open Loop Vector Tune

No.
Name
(Hex.)
n4-60
Motoring Low Speed
Comp Gain
(1B80)
n4-61
Low Speed Comp
Frequency Level
(1B81)
n4-62
Regen Low Speed Comp
Gain
(1B82)
n4-63
Speed
EstimateResponse@
(1B83)
High Freq
n4-64
Speed Estimate
Response@Low Freq
(1B84)
n4-65
Flux Estimate
Response@High Freq
(1B85)
n4-66
Flux Estimate Response
@Low Freq
(1B86)
YASKAWA SIEPC71061705H GA700 Series Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the amount by which the output frequency is to be lowered during high-slip
braking, as a percentage of E1-04 [Maximum Output Frequency], which represents the
100% value.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum current output during high-slip braking as a percentage, where E2-01
[Motor Rated Current (FLA)] is 100%. Also set the current suppression to prevent
exceeding drive overload tolerance.
Note:
The upper limit to the setting range changes when the setting for C6-01 [Normal /
Heavy Duty Selection] changes.
• 150% when C6-01 = 0 [Heavy Duty Rating]
• 110% when C6-01 = 1 [Normal Duty Rating]
V/f
CL-V/f
OLV
CLV
AOLV
Sets the dwell time, a length of time when high-slip braking is ending and during which
the motor speed decreases and runs at a stable speed. For a set length of time, the drive
will hold the actual output frequency at the minimum output frequency set in E1-09.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time used to detect oL7 [High Slip Braking Overload], which occurs when the
output frequency does not change during high-slip braking. Usually it is not necessary
to change this parameter.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain value that the drive multiplies by the V/f pattern output value during
overexcitation deceleration to calculate the overexcitation level.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that injects harmonic signals during overexcitation deceleration.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the upper limit of the current that is suppressed at the time of overexcitation
deceleration as a percentage of the drive rated current.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the direction of motor rotation where the drive will enable overexcitation.
0 : Disabled
1 : Enabled Only when Rotating FWD
2 : Enabled Only when Rotating REV
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets a compensation gain to improve the control qualities for motoring loads in the low
speed range.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a frequency at which the settings n4-60 [Motoring Low Speed Comp Gain] and n4-
62 [Regen Low Speed Comp Gain] are enabled. When the output frequency < n4-61, the
drive adjusts the torque to agree with the settings for n4-60 and n4-62. Usually it is not
necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a compensation gain to improve the control qualities for regenerative loads in the
low speed range.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the responsiveness of the speed estimation in high speed ranges, where the output
frequency is ≥ n4-67 [Estimate Gain Switchover Freq].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the responsiveness of the speed estimation in low speed ranges, where 0 ≤ the
output frequency, which is < n4-67 [Estimate Gain Switchover Freq].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the responsiveness of the magnetic flux estimation in high speed ranges, where the
output frequency is ≥ n4-67 [Estimate Gain Switchover Freq]. Usually it is not
necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the responsiveness of the magnetic flux estimation in low speed ranges, where 0 ≤
the output frequency, which is < n4-67 [Estimate Gain Switchover Freq]. Usually it is
not necessary to change this setting.
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.12 n: Special Adjustment
Default
Ref.
(Range)
5%
922
(1 - 20%)
Determined by C6-01
923
and L8-38
(0 - 150%)
1.0 s
923
(0.0 - 10.0 s)
40 s
923
(30 - 1200 s)
1.10
923
(1.00 - 1.40)
0
924
(0, 1)
100%
924
(0 - 150%)
0
924
(0 - 2)
Default
Ref.
(Range)
100.0%
925
(50.0 - 200.0%)
6.00 Hz
925
(0.50 - 12.00 Hz)
100.0 %
925
(50.0 - 500.0%)
60.0
925
(0.1 - 300.0)
60.0
925
(0.1 - 300.0)
1.00
926
(0.50 - 3.00)
1.50
926
(0.50 - 3.00)
11
559