YASKAWA GA700 Series Technical Manual page 866

Ac drive for industrial applications
Hide thumbs Also See for GA700 Series:
Table of Contents

Advertisement

12.8 H: Terminal Functions
H6-06: Terminal MP Monitor Selection
No.
Name
(Hex.)
H6-06
Terminal MP Monitor
Selection
(0431)
RUN
Note:
To use in through mode or when terminal MP is not used, set this parameter to 000 or 031.
When you use the pulse train monitor, make sure that you connect peripheral devices as specified by these load
conditions:
Incorrect connections can make the characteristics not sufficient or cause mechanical damage.
• Use the pulse train monitor as the sourcing output.
• Use the pulse train monitor as the sinking input
External Power Supply (V)
Sinking current (mA)
H6-07: Terminal MP Frequency Scaling
No.
Name
(Hex.)
H6-07
Terminal MP Frequency
Scaling
(0432)
RUN
When H6-06 = 102 [Terminal MP Monitor Selection = Output Frequency] and H6-07 = 0, the pulse train output
terminal MP outputs the same frequency as the drive output frequency.
H6-08: Terminal RP Minimum Frequency
No.
Name
(Hex.)
H6-08
Terminal RP Minimum
Frequency
(043F)
866
V/f
CL-V/f
OLV
Sets a function for pulse train monitor output terminal MP. Sets the "x-xx" part of the Ux-xx
monitor.
Output Voltage
VRL(V)
5 V or more
8 V or more
10 V or more
Figure 12.118 Circuit Diagram When Used as the Sourcing Output
Figure 12.119 Circuit Diagram When Used as the Sinking Input
V/f
CL-V/f
OLV
Sets the frequency of the pulse train output signal used when the monitor set with H6-06
[Terminal MP Monitor Selection] is 100%.
V/f
CL-V/f
OLV
Sets the minimum frequency of the pulse train signal that terminal RP can detect.
Description
CLV
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
CLV
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
CLV
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA SIEPC71061705H GA700 Series Technical Manual
(000, 031, 101, 102, 105,
116, 501, 502, 801 - 809,
821 - 825, 831 - 839, 851 -
Load Impedance (kΩ)
1.5 kΩ or more
4.0 kΩ or more
10 kΩ or more
12 VDC ± 10%, 15 VDC ± 10%
16 mA or less
(0.1 - 1000.0 Hz)
Default
(Range)
102
855)
Default
(Range)
1440 Hz
(0 - 32000 Hz)
Default
(Range)
0.5 Hz

Advertisement

Table of Contents
loading

Table of Contents