o1-48: Trend Plot 1 Scale Maximum Value
No.
Name
(Hex.)
o1-48
Trend Plot 1 Scale
Maximum Value
(11C8)
RUN
Note:
Parameter o1-47 [Trend Plot 1 Scale Minimum Value] sets the lower limit. The lower limit is (o1-47 + 0.1)%.
o1-49: Trend Plot 2 Scale Minimum Value
No.
Name
(Hex.)
o1-49
Trend Plot 2 Scale
Minimum Value
(11C9)
RUN
Note:
Parameter o1-50 [Trend Plot 2 Scale Maximum Value] sets the upper limit. The upper limit is (o1-50 - 0.1)%.
o1-50: Trend Plot 2 Scale Maximum Value
No.
Name
(Hex.)
o1-50
Trend Plot 2 Scale
Maximum Value
(11CA)
RUN
Note:
Parameter o1-49 [Trend Plot 2 Scale Minimum Value] sets the lower limit. The lower limit is (o1-49 + 0.1)%.
o1-51: Trend Plot Time Scale Setting
No.
Name
(Hex.)
o1-51
Trend Plot Time Scale
Setting
(11CB)
RUN
o1-55: Analog Gauge Area Selection
No.
Name
(Hex.)
o1-55
Analog Gauge Area
Selection
(11EE)
RUN
0 : +/- Area ( - o1-56 ~ o1-56 )
1 : + Area ( 0 ~ o1-56 )
o1-56: Analog Gauge Area Setting
No.
Name
(Hex.)
o1-56
Analog Gauge Area Setting
(11EF)
RUN
o1-58: Motor Power Unit Selection
No.
Name
(Hex.)
o1-58
Motor Power Unit Selection
(3125)
The drive shows these parameter values in the set units:
YASKAWA SIEPC71061705H GA700 Series Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum value for the vertical axis used to display the monitor that was set in o1-24
[Custom Monitor 1] as a trend plot. This parameter is only available with an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the horizontal axis minimum value used to display the monitor set in o1-25 [Custom Monitor
2] as a trend plot. This parameter is only available with an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum value for the vertical axis used to display the monitor that was set in o1-25
[Custom Monitor 2] as a trend plot. This parameter is only available with an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time scale (horizontal axis) to display the trend plot. When you change this setting, the
drive automatically adjusts the data sampling time. This parameter is only available with an LCD
keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the range used to display the monitor set in o1-24 [Custom Monitor 1] as an analog gauge.
This parameter is only available with an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the value used to display the monitor set in o1-24 [Custom Monitor 1] as an analog meter.
This parameter is only available with an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the setting unit for parameters that set the motor rated power.
12.11 o: Keypad-Related Settings
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
(Range)
100.0%
(-299.9 - +300.0%)
Default
(Range)
-100.0%
(-300.0 - +299.9%)
Default
(Range)
100.0%
(-299.9 - +300.0%)
Default
(Range)
300 s
(1 - 3600 s)
Default
(Range)
1
( 0, 1 )
Default
(Range)
100.0%
(0.0 - 100.0%)
Default
(Range)
0
(0, 1)
12
947