YASKAWA GA700 Series Technical Manual page 935

Ac drive for industrial applications
Hide thumbs Also See for GA700 Series:
Table of Contents

Advertisement

n8-37: HFI Voltage Amplitude Level
No.
Name
(Hex.)
n8-37
HFI Voltage Amplitude
Level
(0564)
Expert
Note:
• Set n8-35 = 1 [Initial Pole Detection Method = High Frequency Injection] or n8-57 = 1 [HFI Overlap Selection = Enabled] to enable
this parameter.
• The drive automatically calculates this value when High Frequency Injection Auto-Tuning completes successfully.
n8-39: HFI LPF Cutoff Freq
No.
Name
(Hex.)
n8-39
HFI LPF Cutoff Freq
(0566)
Note:
• Set n8-35 = 1 [Initial Pole Detection Method = High Frequency Injection] or n8-57 = 1 [HFI Overlap Selection = Enabled] to enable
this parameter.
• The drive automatically calculates this value when High Frequency Injection Auto-Tuning completes successfully.
n8-41: HFI P Gain
No.
Name
(Hex.)
n8-41
HFI P Gain
(0568)
Expert
Note:
• Set n8-35 = 1 [Initial Pole Detection Method = High Frequency Injection] or n8-57 = 1 [HFI Overlap Selection = Enabled] to enable
this parameter.
• When A1-02= 6 [Control Method Selection = AOLV/PM] and you do High Frequency Injection Auto-Tuning, the drive automatically
sets this parameter .
• Set n8-41 > 0.0 for IPM motors.
Set this parameter as follows.
• If there is oscillation or hunting, decrease the setting in units of 0.5.
• When it is necessary to track load changes, increase the setting in units of 0.5.
n8-42: HFI I Time
No.
Name
(Hex.)
n8-42
HFI I Time
(0569)
Expert
Note:
Set n8-35 = 1 [Initial Pole Detection Method = High Frequency Injection] or n8-57 = 1 [HFI Overlap Selection = Enabled] to enable
this parameter.
n8-45: Speed Feedback Detection Gain
No.
Name
(Hex.)
n8-45
Speed Feedback Detection
Gain
(0538)
Adjust this parameter in these conditions:
• If vibration or hunting occur, increase the setting value in 0.05 unit increments.
• If the responsiveness of torque and speed is unsatisfactory, decrease the setting value 0.05 unit increments and
examine the response.
YASKAWA SIEPC71061705H GA700 Series Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the high frequency injection amplitude as a percentage where 200 V = 100% for 200 V class
drives and 400 V = 100% for a 400 V class drives. Usually it is not necessary to change this
setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the low-pass filter shut-off frequency for high frequency injection.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the response gain for the high frequency injection speed estimation.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the integral time constant for the high frequency injection speed estimation. Usually it is not
necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the internal speed feedback detection reduction unit gain as a magnification value. Usually it
is not necessary to change this setting.
12.10 n: Special Adjustment
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
(Range)
20.0%
(0.0 - 50.0%)
Default
(Range)
250 Hz
(0 - 1000 Hz)
Default
(Range)
2.5
(-10.0 - +10.0)
Default
(Range)
0.10 s
(0.00 - 9.99 s)
Default
(Range)
0.80
(0.00 - 10.00)
12
935

Advertisement

Table of Contents
loading

Table of Contents