L4: Speed Detection - YASKAWA GA700 Series Technical Manual

Ac drive for industrial applications
Hide thumbs Also See for GA700 Series:
Table of Contents

Advertisement

No.
Name
(Hex.)
L3-21
OVSuppression Accel/
Decel P Gain
(0466)
Expert
L3-22
PM Stall Prevention
Decel Time
(04F9)
L3-23
Stall P Reduction at
Constant HP
(04FD)
L3-24
Motor Accel Time @
Rated Torque
(046E)
Expert
L3-25
Load Inertia Ratio
(046F)
Expert
L3-26
Additional DC Bus
Capacitors
(0455)
Expert
L3-27
Stall Prevention
Detection Time
(0456)
L3-34
Torque Limit Delay
Time
(016F)
Expert
L3-35
Speed Agree Width for
Auto Decel
(0747)
Expert
L3-36
Current Suppression
Gain@Accel
(11D0)
L3-37
Current Limit P Gain @
Accel
(11D1)
Expert
L3-38
Current Limit I Time @
Accel
(11D2)
Expert
L3-39
Current Limit Filter
Time @Accel
(11D3)
L3-40
Current Limit S-Curve
@ Acc/Dec
(11D4)

L4: Speed Detection

No.
Name
(Hex.)
L4-01
Speed Agree Detection
Level
(0499)
L4-02
Speed Agree Detection
Width
(049A)
YASKAWA SIEPC71061705H GA700 Series Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the proportional gain to calculate acceleration and deceleration rates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the momentary deceleration time that the drive will use when it tries to accelerate a
PM motor and detected motor stalls. This function is applicable when L3-01 = 1 [Stall
Prevention during Accel = Enabled].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to automatically decrease the Stall Prevention Level during Run for
Constant Horse Power (CHP) part of the speed range.
0 : Use L3-06 for Entire Speed Range
1 : Automatic Reduction @ CHP Region
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor acceleration time to reach the maximum frequency at the motor rated
torque for stopped single-drive motors.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the ratio between motor inertia and machine inertia.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the capacity for external main circuit capacitors. Usually it is not necessary to
change this setting. Sets this parameter when you use the KEB Ride-Thru function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a delay time between reaching the Stall Prevention level and starting the Stall
Prevention function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the filter time constant that returns the torque limit to its initial value when KEB
operation operates in Single Drive KEB Ride-Thru mode.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the width for speed agreement when L3-04 = 2 [Stall Prevention during Decel =
Intelligent (Ignore Decel Ramp)]. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain to suppress current and motor speed hunting during operation when L3-01
= 3 [Stall Prevention during Accel = Current Limit Method]. Usually it is not necessary
to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Suppresses current hunting during acceleration. Usually it is not necessary to change
this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Suppresses current hunting and overshooting that occurs when the drive stalls during
acceleration. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time constant to adjust the acceleration rate when L3-01 = 3 [Stall Prevention
during Accel = Current Limit Method]. Usually it is not necessary to change this
setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to enable and disable the best S-curve characteristic used for current-
limited acceleration.
0 : Disable
1 : Enabled
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the level to detect speed agree or motor speed.
Sets the level to detect speed agree or motor speed when H2-01 to H2-03 = 2, 3, 4, 5
[MFDO Function Selection = Speed Agree 1, User-set Speed Agree 1, Frequency
Detection 1, Frequency Detection 2].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the width to detect speed agree or motor speed.
Sets the width to detect speed agree or motor speed when H2-01 to H2-03 = 2, 3, 4, 5
[MFDO Function Selection = Speed Agree 1, User-set Speed Agree 1, Frequency
Detection 1, Frequency Detection 2].
11.11 L: Protection Functions
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
Ref.
(Range)
Determined by A1-02
893
(0.10 - 10.00)
0.0 s
893
(0.0 - 6000.0 s)
0
893
(0, 1)
Determined by o2-04,
893
C6-01, E2-11, and E5-01
(0.001 - 10.000 s)
1.0
894
(0.1 - 1000.0)
0 μF
894
(0 to 65000 μF)
50 ms
895
(0 - 5000 ms)
Determined by A1-02
895
(0.000 - 1.000 s)
0.00 Hz
895
(0.00 - 1.00 Hz)
Determined by A1-02
895
(0.0 - 100.0)
5 ms
895
(0 - 100 ms)
10.0
895
(0.0 - 100.0)
100.0 ms
896
(1.0 - 1000.0 ms)
0
896
(0, 1)
Default
Ref.
(Range)
Determined by A1-02
896
(Determined by A1-02)
Determined by A1-02
896
(Determined by A1-02)
551