12.12 T: Auto-Tuning
T2-03: PM Motor Type
No.
Name
(Hex.)
T2-03
PM Motor Type
(0752)
0 : IPM motor
IPM motors have magnets in the rotor, and Ld ≠ Lq.
1 : SPM motor
SPM motors have magnets attached to the surface of the rotor with adhesive material, and Ld = Lq.
T2-04: PM Motor Rated Power
No.
Name
(Hex.)
T2-04
PM Motor Rated Power
(0730)
T2-05: PM Motor Rated Voltage
No.
Name
(Hex.)
T2-05
PM Motor Rated Voltage
(0732)
T2-06: PM Motor Rated Current
No.
Name
(Hex.)
T2-06
PM Motor Rated Current
(0733)
T2-07: PM Motor Base Frequency
No.
Name
(Hex.)
T2-07
PM Motor Base Frequency
(0753)
T2-08: Number of PM Motor Poles
No.
Name
(Hex.)
T2-08
Number of PM Motor Poles
(0734)
T2-09: PM Motor Base Speed
No.
Name
(Hex.)
T2-09
PM Motor Base Speed
(0731)
T2-10: PM Motor Stator Resistance
No.
Name
(Hex.)
T2-10
PM Motor Stator Resistance
(0754)
Note:
This parameter does not set line-to-line resistance.
966
V/f
CL-V/f
OLV
CLV
AOLV
Sets the type of PM motor the drive will operate.
V/f
CL-V/f
OLV
CLV
AOLV
Uses the units set in o1-58 [Motor Power Unit Selection] to set the PM motor rated output power.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated voltage (V) of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated current (A) of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the base frequency (Hz) of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of motor poles.
V/f
CL-V/f
OLV
CLV
AOLV
-1
Sets the motor base speed (min
(r/min)).
V/f
CL-V/f
OLV
CLV
AOLV
Sets the stator resistance for each motor phase.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA SIEPC71061705H GA700 Series Technical Manual
Default
(Range)
1
(0, 1)
Default
(Range)
Determined by o2-04, C6-
01
(0.00 - 650.00 kW)
Default
(Range)
200 V Class: 200.0 V,
400 V Class: 400.0 V
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
Default
(Range)
Determined by o2-04
(10% to 200% of the drive
rated current)
Default
(Range)
87.5 Hz
(0.0 - 590.0 Hz)
Default
(Range)
6
(2 - 120)
Default
(Range)
-1
1750 min
(r/min)
-1
(0 - 34500 min
(r/min))
Default
(Range)
Determined by T2-02
(0.000 - 65.000 Ω)