YASKAWA GA700 Series Technical Manual page 815

Ac drive for industrial applications
Hide thumbs Also See for GA700 Series:
Table of Contents

Advertisement

43: FWD/REV (2-Wire Sequence 2)
Setting Value
Function
43
FWD/REV (2-Wire
Sequence 2)
ON : Reverse Run
OFF : Forward Run
Note:
• You must input the Run command to rotate the motor.
• This function will not operate at the same time as H1-xx = 40, 41 [Forward RUN (2-Wire), Reverse RUN (2-Wire)].
44: Add Offset Frequency 1 (d7-01)
Setting Value
Function
44
Add Offset Frequency 1
(d7-01)
Note:
Refer to
d7: Offset Frequency on page 737
45: Add Offset Frequency 2 (d7-02)
Setting Value
Function
45
Add Offset Frequency 2
(d7-02)
Note:
Refer to
d7: Offset Frequency on page 737
46: Add Offset Frequency 3 (d7-03)
Setting Value
Function
46
Add Offset Frequency 3
(d7-03)
Note:
d7: Offset Frequency on page 737
Refer to
47: Node Setup (CANopen)
Setting Value
Function
47
Node Setup (CANopen)
60: DC Injection Braking Command
Setting Value
Function
60
DC Injection Braking
Command
If you input the Run command or JOG command, it will cancel DC Injection Braking.
Figure 12.88
shows the time chart of the DC Injection Braking function.
YASKAWA SIEPC71061705H GA700 Series Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the direction of motor rotation for 2-wire sequence 2. Set this function and H1-xx = 42 [Run Command (2-Wire Sequence
2)] together.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to add the offset frequency set in d7-01 [Offset Frequency 1] to the frequency reference when the terminal
activates.
for more information.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to add the offset frequency set in d7-02 [Offset Frequency 2] to the frequency reference when the terminal
activates.
for more information.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to add the offset frequency set in d7-03 [Offset Frequency 3] to the frequency reference when the terminal
activates.
for more information.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function in CANopen communications to start the Node Setup function to set the drive node address from the host
controller.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the command to use DC Injection Braking to stop the motor.
12.8 H: Terminal Functions
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
12
815

Advertisement

Table of Contents
loading

Table of Contents