③ Addition of PSE [JOHB-SMP3 Protocol Set Error]
This error is issued when the DIP switch setting is inappropriate.
*In PRG: 01034 or earlier, this is oFA00 [Option Not Compatible with Port].
Display (Hex.)
PSE (0437)
Code
PSE
Register number (Hex.)
00F5
Table 2.3 Specifications of PSE Fault Code
Name
JOHB-SMP3 Protocol Set
Error
Table 2.4 Causes and Possible Solutions of PSE Faults
Name
JOHB-SMP3 Protocol Set
Error
Table 2.5 Communication Monitor Data of PSE Faults
Fault Description 12
bit 0-5
bit 6
bit 7-F
ALM LED
Illuminated
Cause
・The DIP switch on the
JOHB-SMP3 is at its default
setting.
・The protocol of
JOHB-SMP3 has not been
assigned.
Description
Reserved
PSE [JOHB-SMP3 Protocol Set Error]
Reserved
Type
Fault
Possible Solutions
・Turn the drive OFF, then
reset the DIP switch on the
JOHB-SMP3 to a protocol
assigned state.
※For details on DIP switch
specifications, refer to the
manual for JOHB-SMP3.